Signalbetinger for lastcelleinput  - Discontinued

DRF-LC

Signalbetinger for lastcelleinput | DRF-LC

Signalbetinger for lastcelleinput

244,65 DRF-LC-24VDC-30MV-4/20

1 year warranty CE
  • Til lastceller med output 1 mV/V, 2 mV/V
    og 3 mV/V
  • Fuld skala ved 10 mV, 20 mV og 30 mV
  • Jumper før tara ved 50 %, 25 % og 0 %
  • Nøjagtighed 0,2 %
  • Reaktionstid < 75 msek.
  • Galvanisk isolering mellem input, output og effekt

Beskrivelse

The DRF-LC series is no longer available. Please refer to our TXDIN1600S or DRC-4710 and 4720 as an alternative

.
The DRF series DIN rail signal conditioners are designed to accept a broad range of input signals, such as ac and dc voltage and current, frequency, temperature (thermocouple and RTD), and process transducers, and provide standard process outputs of either 4 to 20 mA, or 0 to 10 Vdc. The DRF series feature a modern housing design, that is easily mounted on standard 35 mm DIN rails. Connections are safely and securely made through pluggable screw terminal connectors, with input and output connections on the opposite sides of the module.

The DRF-LC signal conditioner accepts a load cell input and provides an isolated 0 to 10 Vdc or 4 to 20 mA output. Models are available with three different power options, 24 Vdc, 115 Vac and 230 Vac.

The DRF-LC are ideally suited for industrial applications. The DRF-LC feature galvanic isolation between input, output and power up to 3500 Veff (model specific). Module response time is 75 ms or less.

The FAR-1 power supply is an ideal companion product for the DRF-LC. It provides a regulated 10Vdc output that may be used to power up to 4 load cells.

Range Code Table
Range CodeRange
10MV0 to 10 mV
20MV0 to 20 mV
30MV0 to 30 mV


SPECIFICATIONS

Accuracy: <0.2% full scale
Linearity: <<0.1% full scale
Thermal Drift: 250 ppm/°C typical (max <200ppm/°C)
Response Time: <75 mS (90% of signal)
Bandwith: 20 Hz (-3dB)
Pretare: 50%, 25% and 0% by jumpers
Impedance: 5 M Ω
Over Range Protection: 15 V max differential input

Power: 24 Vdc ±10%, 230 Vac ±10% 50/60 Hz, 115 Vac ±10% 50/60 Hz
Power Consumption: <3.8 VA

Output: 4 to 20 mA and 0 to 10 Vdc
Maximum Voltage Output: 11 Vdc approx.
Minimum Voltage Output: -1 Vdc approx.
Minimum Load Resistance (Voltage): >1 KΩ Maximum Current Output: 22 mA approx.
Maximum Current Output: -1.5 mA approx.
Maximum Load Resistance (current): >400 Ω
 

Electrical Connections: Plug-in screw terminals
Protection: IP-30

MECHANICAL DIMENSIONS
Weight:
(DC Powered Models): 120 g (4.2 oz)
(AC Powered Models): 200 g (7 oz)
Dimensions:
(DC Powered models):
110 H x 22.5 W x 93 mm D
(AC Powered models):
110 H x 37 W x 93 mm D
Operating Temperature: 0 to 60°C
Storage Temperature: -20 to 70°C
Til bestilling(Angiv modelnummer)

Andre har købt: Du kan klikke på dette ikon og få vist en liste over produkter, som andre har købt sammen med denne model.

Vare nummer/Desc.
Antal 
Beskrivelse
Below are examples of popular models. See the Part Number Builder to order any available model.
  
DRF-LC-230VAC-10MV-4/20
Kontakt salgsafdelingen    
Beholdning: 
 
 
Load cell signal conditioner with 0 to 10mV input and 4 to 20 mA output, 230 Vac power
  
DRF-LC-24VDC-10MV-4/20
€252,97
Beholdning: 1 uge 
 
Load cell signal conditioner with 0 to 10mV input and 4 to 20 mA output, 24 Vdc power
  
DRF-LC-115VAC-10MV-4/20
€252,97
Beholdning: 7 uger 
 
Load cell signal conditioner with 0 to 10mV input and 4 to 20 mA output, 115 Vac power
Excitation Power Supplies
All amounts shown in EUR

Delnummerberegner

Build Your Part Number Below
Beskrivelse af tilvalg:


(1) Power select from:
24VDC for 24Vdc power
115VAC for 115Vac power
230VAC for 230Vac power

(2) Input Range Code select from:
10MV for 0 to 10 mV
20MV for 0 to 20 mV
30MV for 0 to 30 mV

(3) Output select from:
4/20 for 4 to 20mA
0/10 for 0 to 10Vdc
Noter: Ikke alle kombinationer er nødvendigvis gyldige. Se specifikationerne for gyldige delnumre.
We noticed you are from the US. Visit your local site for regional offers and live support.