Proximity Switches for Use With FL-500 Series Flowmeters

FL500-R

Proximity Switches for Use With Fl-500 Series Flowmeters | FL500-R

Proximity Switches for Use With Fl-500 Series Flowmeters

168,36 FL-500-RI

1 year warranty
  • Complete Switch Kits, Ready for Installation
  • Easy Switch Point Setting Adjustment to Desired Flow Rate Indication
  • Set High and Low Limits With 2 Proximity Switches
  • One Switch Can Act as Deviation Alarm
Flowmetre med variabelt areal, variable area flow meter & kontakter - Vis relaterede produkter

Beskrivelse

The FL-500-RI proximity switches generate electrical signals at your predetermined flow rates, adding versatility and performance to the FL-500 Series flowmeters. Each switch kit contains all the necessary hardware for quick and trouble-free mounting. Kits consist of a ring-shaped ceramic magnet that fits around the float in the flowmeter and a proximity switch mounted in a rugged housing that easily clamps to the body of the flowmeter. As the changing flow causes the float to move within the tube, the magnet moves with it, and its magnetic field trips the proximity switch at the predetermined flow rate. Adjustment screw allows for easy flow rate adjustment. Add two switches to indicate both high and low flow rate limits.

SPECIFICATIONS
Contact Ratings: 12 Vdc at 0.25 A; 28 Vdc at 0.107 A; 120 Vac at 0.025A (at 77°F)
Dimensions: 152 x 89 mm (6 x 3½")
All amounts shown in EUR
Noter: Switch activates over a 25% of full scale band; above and below this band, the relay deactivates.

Comes complete with one magnet, one switch housing, one foam gasket, two half-collars, four cap screws with lock washers, two nuts, and operator's manual.

Two nuts are needed only when two switches are mounted on one flowmeter.