Cookies på Omegas websteder
Vi anvender cookies på vores websted. Disse cookies er afgørende for, at webstedet kan fungere korrekt.
Hvis du fortsætter uden at ændre dine indstillinger, antager vi, at du gerne vil modtage alle de cookies, der anvendes på dette websted. Du finder flere oplysninger om cookies ved at klikke her
Luk
Kurv  |  Kontakt  | 
GRATIS TELEFON (Kun Danmark. Alle opkald besvares på engelsk) 80 25 14 43
INTERNATIONAL(+45) 80 25 14 43
Layer N Banner

Explosion Proof / Flame Proof and IS Rated
Pressure Transmitter for Hazardous Locations

PX835 Series

Explosion Proof / Flame Proof and IS Rated Pressure Transmitter for Hazardous Locations | PX835 Series

747,86 PX835-100GI

CE
  • Oil Field Equipment
  • Upstream Oil and Gas Production
  • Natural Gas Compression and Transfer Control
  • Alternative Energy Projects
  • Fuel Cell Manufacturing
  • UL Explosion Proof
  • ATEX Flame Proof
  • FM & CSA Intrinsically Safe
Tryktransducere - Vis relaterede produkter

Beskrivelse

The PX835 explosion proof / flame proof pressure transmitter is ideal for a broad spectrum of pressure sensing requirements, requiring hazardous location approvals for explosion proof, flame proof or intrinsically safe. The PX835 is designed with an all welded stainless steel case and manufactured to provide the user with accurate, reliable, and stable output data. This is accomplished through the use of state of the art sensor technology combined with digital calibration to provide extremely linear and precise performance over the entire specified pressure and temperature range.

SPECIFICATIONS
Output: 4 to 20 mAdc (2-wire)
Supply Voltage: 12 to 32 Vdc Vmin = 12 V + (0.022A x loop res)
Insulation Resistance (Circuit to Case): 100M Ω @ 30 Vdc
Circuit Protection: Reverse polarity and mis-wire protected
Accuracy: ±0.5% TP; ±0.40% BFSL includes non-linearity, hysteresis and non-repeatability, zero offset and span setting errors (add 0.05% for ranges above 5000 psi)
Stability: ≤±0.25% span/year @ ref conditions (21°C/70°F)
Response Time: 2 ms
Storage/Process/Operating Temperature: -40 to 125°C (-40 to 257°F)
Compensated Temperature: -20 to 85°C (-4 to 185°F)
Temperature Effects (Over Comp Range): 2% span
Humidity Effects: No performance effects 0 to 95% RH, non-condensing
Vibration:
    Shock: 100 g peak, 11 ms
    Random: 10 g RMS, 20 to 2000 Hz
    Sweep: 50 to 2000 Hz, 5 g peak
Position Effect: ±0.02% typical
Electrical Termination: ½ NPT male conduit fitting and 4.6 m (15') cable with flying lead termination
Pressure Connection: ¼ NPT male
Environmental Rating: NEMA 7, 9 (IP65)
Hazardous Area Certifications:
    Explosion Proof - cUL (USA/CNL):
    Specify PX835; Class I, Div 1 & 2, Groups A, B, C, and D; Class II, Div 1 & 2, Groups E, F, and G
    Flame Proof - ATEX: Specify PX835 II 2 G; Ex d IIC T4
    Intrinsically Safe - FM/CSA: Class I, Div 1; Class I, Div 2, non-incendive
    CE Compliance: EN 61326: 1997 + A1: 1998 Annex A, A2/2001 Heavy Industrial Immunity (Annex A table A.1); Light Industrial/Residential Emission (Table 4)
Wetted Parts: 316SS diaphragm and pressure port
Case: 304 SS
Cable Gland: Fits cable diameter 9 to 12 mm (0.35 to 0.47")
Weight: Approximately 254 g (8 oz)
Til bestilling(Angiv modelnummer)
Vare nummer/Desc.
Antal 
Beskrivelse
Vacuum and Compound Ranges
PX835-15NGI
785,53
Beholdning: 11 uger 
 
Range; 0 psig to Vac, 0 to -1 bar
PX835-015CGI
856,25
Beholdning: 6 uger 
 
Range; Vac to 15 psi, -1 to +1 bar
PX835-030CGI
747,66
Beholdning: 11 uger 
 
Range; Vac to 30 psi, -1 to +2 bar
PX835-045CGI
816,73
Beholdning: 11 uger 
 
Range; Vac to 45 psi, -1 to +3 bar
PX835-060CGI
785,53
Beholdning: 11 uger 
 
Range; Vac to 60 psi, -1 to +4 bar
PX835-100CGI
747,66
Beholdning: 1 uge 
 
Range; Vac to 100 psi, -1 to +7 bar
Gauge Pressure Ranges
PX835-005GI
828,09
Beholdning: 1 uge 
 
Range; 0 to 5 psi, 0 to 0.3 bar
PX835-010GI
823,53
Beholdning: 11 uger 
 
Range; 0 to 10 psi, 0 to 0.7 bar
PX835-015GI
828,09
Beholdning: 11 uger 
 
Range; 0 to 15psi , 0 to 1 bar
PX835-030GI
816,73
Beholdning: 11 uger 
 
Range; 0 to 30 psi, 0 to 2 bar
PX835-060GI
816,73
Beholdning: 11 uger 
 
Range; 0 to 60 psi, 0 to 4 bar
PX835-100GI
747,86
Beholdning: 11 uger 
 
Range; 0 to 100 psi, 0 to 7 bar
PX835-150GI
Kontakt salgsafdelingen    
Beholdning: 
 
 
Range; 0 to 150 psi, 0 to 10 bar
PX835-200GI
747,66
Beholdning: 5 uger 
 
Range; 0 to 200 psi, 0 to 14 bar
PX835-300GI
773,24
Beholdning: 3 uger 
 
Range; 0 to 300 psi, 0 to 20 bar
PX835-500GI
747,66
Beholdning: 11 uger 
 
Range; 0 to 500 psi, 0 to 34 bar
PX835-750GI
785,53
Beholdning: 11 uger 
 
Range; 0 to 750 psi, 0 to 51 bar
PX835-1KGI
789,87
Beholdning: 11 uger 
 
Range; 0 to 1000 psi, 0 to 69 bar
PX835-2KGI
789,87
Beholdning: 11 uger 
 
Range; 0 to 2000 psi, 0 to138 bar
PX835-3KGI
789,87
Beholdning: 11 uger 
 
Range; 0 to 3000 psi, 0 to 207 bar
PX835-5KGI
773,24
Beholdning: 11 uger 
 
Range; 0 to 5000 psi, 0 to 345 bar
PX835-7.5KGI
747,66
Beholdning: 1 uge 
 
Range; 0 to 7500 psi, 0 to 517 bar
PX835-10KGI
749,26
Beholdning: 11 uger 
 
Range; 0 to 10,000 psi, 0 to 690 bar
All amounts shown in EUR
Noter: Comes complete with 9-point NIST traceable calibration and operating instructions. For oxygen cleaning, add suffix “-X6B” to model number, for additional cost.
We noticed you are from the US. Visit your local site for regional offers and live support.