Discontinued

Wi8 Series

 | Wi8 Series

Se Alt Models Below

1 year warranty CE
  • Brugervenlig, nem at konfigurere
  • Kan anvendes med UWTC- og UWRTD-serierne, trådløs Pt100 og termokoblertransmittere
  • Scanner automatisk op til 8 transmittere
  • Ethernet-interface med integreret webserver - gør det muligt at foretage overvågning af data i realtid og registrering på en PC via en standardbrowser
  • 2 alarmudgange: Solid-state-relæer (SSR), DC-impuls, mekaniske relæer, analog spænding & strømstyrke

Beskrivelse

wiSeries Wireless Monitoring and Control System
The OMEGA wiSeries wireless monitoring and control system features meters and scanners compatible with a large and growing number of OMEGA™ wireless sensors:
UWTC: Wireless Thermocouple Transmitters; Type J, K, T, E, R, S, B, N, and C.
UWRTD: Wireless Pt100 Temperature Transmitters
UWTC-NB9/UWRTD-NB9: Industrial Pt100 and Thermocouple Probes with In-Head Wireless Transmitters
UWIR: Wireless Infrared Temperature Sensor & Transmitter
UWXL-TC and UWXL-RTD: Rugged Thermocouple and Pt100 Transmitters in Industrial Housings
zSeries: Wireless Wall-Mount Temperature Transmitters with Integral Sensor.

The wiSeries 1/8 DIN Panel Meter & Controller can monitor up to eight (8) wireless sensors.
The compact instrument connects directly to an Ethernet network and the Internet and features OMEGA's award-winning embedded Web Server. It is easily configured and monitored with a Web browser over the Ethernet network or the Internet.
Alternatively, the wi8 meter-controller can instead be connected to the USB port of a single computer with a "USB Ethernet Adaptor" that are inexpensive and widely available.

MONITOR AND ALARM
The wi8 meter-controller comes standard with a choice of either two Form C relays, or two SSR's (solid state relays) that can be used for control functions or alarms. The wi8 meter can monitor alarm conditions for any or all of the wireless sensors. For example, the wi8 meter can be set up to trip an alarm if any one of the sensors indicated it was above or below a pre-set alarm point.

MONITOR AND CONTROL LOCALLY AND OVER THE INTERNET
The OMEGA™ wiSeries wireless monitoring and control system provides local monitoring and control, along with remote Web-based monitoring of temperature from thermocouple, Pt100 and semiconductor sensors.
The wireless sensors transmit up to 120m (without obstructions or interference) to a wiSeries monitor-controller connected directly to an Ethernet network and the Internet. The wireless system complies with IEEE 802.15.4 operating at 2.4 GHz.
The OMEGA wiSeries system let's you monitor and record measurements over an Ethernet network or the Internet without any special software - just your Web Browser.

WIRELESS SENSORS OMEGA offers a wide and growing selection of wireless sensors for a variety of applications. Depending on application, the wireless sensors run on either batteries or AC power. The AC version comes with a universal AC Adaptor that operates on any voltage worldwide from 100 to 240 Vac, and includes a single lithium back-up battery. Wireless sensors are available with external probes appropriate for an almost unlimited variety of industrial and commercial applications.

ETHERNET
The wiSeries meter-controller-scanner is an independent node on the network sending and receiving data in standard TCP/IP packets. It is easily configured from a Web Browser and can be password protected. From within an Ethernet LAN or over the Internet, the user simply types the IP address (such as 192.168.1.200) or an easy to remember name (such as "Oven 5" or "Engine Test Bay") and the wiSeries meter serves a Web Page with the current readings.

ALARM AND EMAIL
The wiSeries meter can trigger an alarm if variables go above or below a set point that you determine. Your alarm can be sent by email to a single user or to a group distribution list. OMEGA Enterprise Gateway software is a free and easy program for this application. The wiSeries meter-controllers operate on any AC voltage worldwide from 100 to 240 Vac and 50 to 60 Hz. The metercontroller connects directly to an Ethernet Network or the Internet. Unlike an RS232 or USB device, it does not require a host computer.

EMBEDDED WEBSERVER
The OMEGA wiSeries wireless sensor system is easy to install, simple to operate, and features OMEGA's award-winning iServer technology with an Embedded Web Server that requires no special software.

CHARTS AND GRAPHS
The OMEGA wiSeries system serves Active Web Pages to display real time readings and charts of temperature, humidity, and barometric pressure. You can also log data in standard data formats for use in a spreadsheet or data acquisition program such as Excel or Visual Basic. OMEGA offers a free and easy to use program for logging data to Excel.
The virtual chart viewed on the web page is a JAVA Applet that records a chart over the LAN or Internet in real time. With the OMEGA wiSeries system there is no need to invest time and money learning a proprietary software program to log or chart the data.
Chart scales are fully adjustable on the fly. For example, the chart can display one minute, one hour, one day, one week, one month or one year. Temperature and humidity can be charted across the full span (-40 to 125°C) or within any narrow range such as (20 to 30°C).
OMEGA offers an OPC Server software (additional charge) that makes it easy to integrate the wiSeries wireless sensor system with many popular Data Acquisition and Automation programs offered by Omega, Wonderware, iConics, Intellution, Rockwell Automation, and National Instruments, among others.

PROGRAMMABLE COLOUR DISPLAY
The OMEGA wiSeries feature OMEGA's patented programmable colour displays. The display can be programmed to change colour at any set point or alarm point.
For example, the instrument can be programmed to display the process value in GREEN during warmup, switching to AMBER to signal the normal operating range, and in RED to signal an alarm condition. The changes in colour are quickly seen from a distance, and machine operators can intuitively react to changing conditions. The colours can be programmed to change back when the value drops back below the alarm point or to "latch" on until being reset by the operator.
The instrument can also be programmed to display only one unchanging colour: GREEN, AMBER, or RED. This is a useful way to let an operator identify, at a glance, process values in three separate locations, or to display three different measurements.

QUALITY AND TECHNOLOGY
Designed and manufactured in the USA, the innovative OMEGA™ wiSeries of meters and controllers features an extended 1 year warranty at no extra charge.

SPECIFICATIONS
Input Types:
UWTC: Wireless Thermocouple Transmitters; Type J, K, T, E, R, S, B, N, and C.
UWRTD: Wireless Pt100 Temperature Transmitters
UWTC-NB9/UWRTD-NB9: Industrial Pt100 and Thermocouple Probes with In-Head Wireless Transmitters
UWIR: Wireless Infrared Temperature Sensor & Transmitter
UWXL-TC and UWXL-RTD: Rugged Thermocouple and Pt100 Transmitters in Industrial Housings
zSeries: Wireless Wall-Mount Temperature Transmitters with Integral Sensor.
Refer to individual wireless products for their specifications.


Control Output 1 & 2 Relay: 250 Vac or 30 Vdc @ 3A (resistive load); configurable for ON/OFF
Output 1: SPDT type, can be configured as Alarm 1 output
Output 2: SPDT type, can be configured as Alarm 2 output
SSR: 20 to 265 Vac @ 0.05 to 0.5A (resistive load); continuous
DC Pulse: Non-Isolated; 10 Vdc @ 20 mA

Alarm 1 & 2 (programmable)
Type: Same as Output 1 and 2
Operation: High/low, above/below, band, latch/unlatch, normally open/normally closed and process/deviation; front panel configurations
Analogue Output (programmable): Non-Isolated, Retransmission 0 to 10Vdc or 0 to 20mA, 500Ω max (Output 1 only). Accuracy is ± 1% of FS when following conditions are satisfied. 1) Input is not scaled below 1% of Input FS. 2) Analogue Out is not scaled below 3% of Output FS.

Network and Communications
Ethernet: Standards Compliance IEEE 802.3 10Base-T
Supported Protocols: TCP/IP, ARP
LED Indicators: Network Activity, Network Link, Diagnostics, Receive & Power
Management: Device configuration and monitoring through embedded WebServer
Embedded WEB Server: Serves WEB pages ( JAVA Applets) containing real-time data and live updated charts within definable time intervals.
Software: OMEGA Enterprise Gateway


Wireless Communication
Standard: IEEE 802.15.4
Frequency: 2.4 GHz (2410MHz), 12 Channels (for wi8xx-U)
2.4 GHz (2410MHz), 16 Channels (for wi8xx-zT)
Network Topology: Star Topology
Range:
UWTC-1, UWRTD-1: up to 60 m (200 ft) without obstructions or interference.
UWTC-2, UWRTD-2, UWIR-2-NEMA: up to 120 m (400 ft) without obstructions or interference.
UWXL: up to 120 m (400 ft) without obstructions or interference.
zED-*: up to 91 m (300 ft) without obstructions or interference.
zED-*-P, zED-*-LCD, zED-*-TC, zED-*-CCELL: up to 91 m (300 ft) without obstructions or interference.


General
Display: 4-digit, 9-segment LED, 10 mm and 21 mm, red, green and amber programmable colours
Decimal Selection: None for wi8xx-U; None and 0.1 for wi8xx-zT
Connection: Screw terminals
wi8 Dimensions: 48 H x 96 W x 127 mm D
Panel Cutout: 45 H x 92 mm W, 1/8 DIN
Operating Temp: 0 to 55°C, 90% RH non-condensing
Protection : IP10 NEMA-1/Type 1 front panel
Line Voltage/Power: 90 - 240 Vac ±10%, 50 - 400 Hz*, 110 - 375 Vdc, equivalent voltage, 5W
*No CE compliance above 60 Hz
Low Voltage/Power Option: 24 Vac**, 20 - 36 Vdc, 4W.
External power source must meet Safety Agency Approvals
** Units can be powered safely with 24Vac power, but no certification for CE are claimed
Note: A complete wireless system requires at least: one (1) End Device (zED-T* or UWTC-*) and one (1) Coordinator/Receiver (wi8xx-zT or wi8xx-U).
All amounts shown in EUR
Noter: Other outputs options are available, please contact our Sales Department.