Cookies på Omegas websteder Vi anvender cookies på vores websted. Disse cookies er afgørende for, at webstedet kan fungere korrekt. Hvis du fortsætter uden at ændre dine indstillinger, antager vi, at du gerne vil modtage alle de cookies, der anvendes på dette websted. Du finder flere oplysninger om cookies ved at klikke her
wiSeries Wireless Monitoring
and Control System
The OMEGA wiSeries wireless monitoring
and control system features meters and scanners
compatible with a large and growing number of
OMEGA™ wireless sensors:
UWTC: Wireless Thermocouple Transmitters; Type J, K, T, E, R, S, B, N, and C.
UWRTD: Wireless Pt100 Temperature Transmitters UWTC-NB9/UWRTD-NB9: Industrial Pt100 and Thermocouple Probes with In-Head Wireless Transmitters UWIR: Wireless Infrared Temperature Sensor & Transmitter
UWXL-TC and UWXL-RTD: Rugged Thermocouple and Pt100 Transmitters in Industrial Housings zSeries: Wireless Wall-Mount Temperature Transmitters with Integral Sensor.
The wiSeries 1/8 DIN Panel Meter & Controller can
monitor up to eight (8) wireless sensors.
The compact instrument connects directly to an
Ethernet network and the Internet and features
OMEGA's award-winning embedded Web Server. It is
easily configured and monitored with a Web browser
over the Ethernet network or the Internet.
Alternatively, the wi8 meter-controller can instead be
connected to the USB port of a single computer with a
"USB Ethernet Adaptor" that are inexpensive and widely available.
MONITOR AND ALARM
The wi8 meter-controller comes standard with a
choice of either two Form C relays, or two SSR's (solid
state relays) that can be used for control functions or
alarms. The wi8 meter can monitor alarm conditions
for any or all of the wireless sensors. For example, the
wi8 meter can be set up to trip an alarm if any one of
the sensors indicated it was above or below a pre-set
alarm point.
MONITOR AND CONTROL LOCALLY AND
OVER THE INTERNET
The OMEGA™ wiSeries wireless monitoring and
control system provides local monitoring and control,
along with remote Web-based monitoring of
temperature from thermocouple, Pt100 and
semiconductor sensors.
The wireless sensors transmit up to 120m (without obstructions or interference)
to a wiSeries monitor-controller connected directly
to an Ethernet network and the Internet. The wireless
system complies with IEEE 802.15.4 operating at
2.4 GHz.
The OMEGA wiSeries system let's you monitor and
record measurements over an Ethernet network or the Internet
without any special software - just your Web Browser.
WIRELESS SENSORS
OMEGA offers a wide and growing selection of
wireless sensors for a variety of applications.
Depending on application, the wireless sensors run on either batteries or AC power.
The AC version comes with a universal AC Adaptor that
operates on any voltage worldwide from 100 to 240 Vac,
and includes a single lithium back-up battery.
Wireless sensors are available with external probes
appropriate for an almost unlimited variety of industrial
and commercial applications.
ETHERNET
The wiSeries meter-controller-scanner is an
independent node on the network sending and
receiving data in standard TCP/IP packets. It is easily
configured from a Web Browser and can be password
protected. From within an Ethernet LAN or over the
Internet, the user simply types the IP address (such
as 192.168.1.200) or an easy to remember name
(such as "Oven 5" or "Engine Test Bay") and
the wiSeries meter serves a Web Page with the
current readings.
ALARM AND EMAIL
The wiSeries meter can trigger an alarm if variables go
above or below a set point that you determine. Your
alarm can be sent by email to a single user or to a
group distribution list. OMEGA Enterprise Gateway software is a free and easy program for
this application.
The wiSeries
meter-controllers
operate on any
AC voltage
worldwide from
100 to 240 Vac
and 50 to 60 Hz.
The metercontroller
connects directly
to an Ethernet
Network or the Internet. Unlike an RS232 or USB
device, it does not require a host computer.
EMBEDDED WEBSERVER
The OMEGA wiSeries wireless sensor system is easy
to install, simple to operate, and features OMEGA's
award-winning iServer technology with an Embedded
Web Server that requires no special software.
CHARTS AND GRAPHS
The OMEGA wiSeries system serves Active Web
Pages to display real time readings and charts of
temperature, humidity, and barometric pressure. You
can also log data in standard data formats for use in a
spreadsheet or data acquisition program such as Excel
or Visual Basic. OMEGA offers a free and easy to use
program for logging data to Excel.
The virtual chart viewed on the web page is a JAVA
Applet that records a chart over the LAN or Internet in
real time. With the OMEGA wiSeries system there is
no need to invest time and money learning a
proprietary software program to log or chart the data.
Chart scales are fully adjustable on the fly. For
example, the chart can display one minute, one hour,
one day, one week, one month or one year.
Temperature and humidity can be charted across the
full span (-40 to 125°C) or within
any narrow range such as (20 to 30°C).
OMEGA offers an OPC Server software (additional charge) that
makes it easy to integrate the wiSeries wireless sensor
system with many popular Data Acquisition and
Automation programs offered by Omega, Wonderware,
iConics, Intellution, Rockwell Automation, and National
Instruments, among others.
PROGRAMMABLE COLOUR DISPLAY
The OMEGA wiSeries
feature OMEGA's
patented programmable
colour displays. The
display can be
programmed to change
colour at any set point or
alarm point.
For example, the
instrument can be
programmed to display
the process value in
GREEN during warmup,
switching to AMBER
to signal the normal
operating range, and in
RED to signal an alarm
condition. The changes in colour are quickly seen from
a distance, and machine operators can intuitively react
to changing conditions. The colours can be programmed
to change back when the value drops back below the
alarm point or to "latch" on until being reset by the
operator.
The instrument can also be programmed to display
only one unchanging colour: GREEN, AMBER, or RED.
This is a useful way to let an operator identify, at a
glance, process values in three separate locations, or
to display three different measurements.
QUALITY AND TECHNOLOGY
Designed and manufactured in the USA, the
innovative OMEGA™ wiSeries of meters and
controllers features an extended 1 year warranty
at no extra charge.
SPECIFICATIONS Input Types: UWTC: Wireless Thermocouple Transmitters; Type J, K, T, E, R, S, B, N, and C. UWRTD: Wireless Pt100 Temperature Transmitters UWTC-NB9/UWRTD-NB9: Industrial Pt100 and Thermocouple Probes with In-Head Wireless Transmitters UWIR: Wireless Infrared Temperature Sensor & Transmitter UWXL-TC and UWXL-RTD: Rugged Thermocouple and Pt100 Transmitters in Industrial Housings zSeries: Wireless Wall-Mount Temperature Transmitters with Integral Sensor.
Refer to individual wireless products for their specifications.
Control Output 1 & 2 Relay: 250 Vac or 30 Vdc @ 3A (resistive load); configurable for ON/OFF Output 1: SPDT type, can be configured as Alarm 1 output Output 2: SPDT type, can be configured as Alarm 2 output SSR: 20 to 265 Vac @ 0.05 to 0.5A (resistive load); continuous DC Pulse: Non-Isolated; 10 Vdc @ 20 mA
Alarm 1 & 2 (programmable) Type: Same as Output 1 and 2 Operation: High/low, above/below, band, latch/unlatch, normally open/normally closed and process/deviation; front panel configurations Analogue Output (programmable): Non-Isolated, Retransmission 0 to 10Vdc or 0 to 20mA, 500Ω max (Output 1 only). Accuracy is ± 1% of FS when following conditions are satisfied. 1) Input is not scaled below 1% of Input FS. 2) Analogue Out is not scaled below 3% of Output FS.
Network and Communications Ethernet: Standards Compliance IEEE 802.3 10Base-T Supported Protocols: TCP/IP, ARP LED Indicators: Network Activity, Network Link, Diagnostics, Receive & Power Management: Device configuration and monitoring through embedded WebServer Embedded WEB Server: Serves WEB pages ( JAVA Applets) containing real-time data and live updated charts within definable time intervals. Software:OMEGA Enterprise Gateway
Wireless Communication Standard: IEEE 802.15.4 Frequency: 2.4 GHz (2410MHz), 12 Channels (for wi8xx-U)
2.4 GHz (2410MHz), 16 Channels (for wi8xx-zT) Network Topology: Star Topology Range: UWTC-1, UWRTD-1: up to 60 m (200 ft) without obstructions or interference. UWTC-2, UWRTD-2, UWIR-2-NEMA: up to 120 m (400 ft) without obstructions or interference. UWXL: up to 120 m (400 ft) without obstructions or interference. zED-*: up to 91 m (300 ft) without obstructions or interference. zED-*-P, zED-*-LCD, zED-*-TC, zED-*-CCELL: up to 91 m (300 ft) without obstructions or interference.
General Display: 4-digit, 9-segment LED, 10 mm and 21 mm, red, green and amber programmable colours Decimal Selection: None for wi8xx-U; None and 0.1 for wi8xx-zT Connection: Screw terminals wi8 Dimensions: 48 H x 96 W x 127 mm D Panel Cutout: 45 H x 92 mm W, 1/8 DIN Operating Temp: 0 to 55°C, 90% RH non-condensing Protection : IP10 NEMA-1/Type 1 front panel Line Voltage/Power: 90 - 240 Vac ±10%, 50 - 400 Hz*, 110 - 375 Vdc, equivalent voltage, 5W
*No CE compliance above 60 Hz Low Voltage/Power Option: 24 Vac**, 20 - 36 Vdc, 4W.
External power source must meet Safety Agency Approvals
** Units can be powered safely with 24Vac power, but no certification for CE are claimed
Note: A complete wireless system requires at least: one (1) End Device (zED-T* or UWTC-*) and one (1) Coordinator/Receiver (wi8xx-zT or wi8xx-U).
† All amounts shown in EUR Noter: Other outputs options are available, please contact our Sales Department.
We noticed you are from the US. Visit your local site for regional offers and live support.