Heavy Duty Electropneumatic Converters
I/P and E/P Models - NOT CE Compliant - Not for sale in UK/EU

IP510, EP510, IP511, EP511 Series

Heavy Duty Electropneumatic Converters | IP510, EP510, IP511, EP511 Series

Heavy Duty Electropneumatic Converters

985,92 IP511-X27

2 year warranty
  • Hazardous Locations and Intrinsically Safe Ratings
  • NEMA 4X (IP65)
  • 0.1% Accuracy Typical
  • Closed Loop Pressure Feedback Control
  • Built-in Volume Booster Provides Flow Up to 12 SCFM
  • Easy Access to Zero and Span
  • Damping Pot Prevents Overshoot and Hunting
  • Low Air Consumption
  • Mount at Any Angle
  • Compact and Lightweight
  • Virtually No Sensitivity to Supply Pressure Changes
  • Removable Orifice for Easy Maintenance
  • Buna-N Seals Standard, Fluorocarbon Optional
Ventiler, regulatorer og I/P-konvertere - Vis relaterede produkter

Beskrivelse

The IP510/EP510 Series are a patented family of electro-pneumatic instruments that are used to reduce a pneumatic supply pressure to a regulated output pressure which is directly proportional to a two-wire current or three-wire voltage input. This design incorporates closed loop sensing of the output pressure to achieve excellent accuracy and vibration stability. They also feature a unique damping circuit which can be adjusted to prevent overshoot and actuator hunting. Model selection includes General purpose NEMA 1, and Water-tight/Corrosion Resistant NEMA 4X (IP65). All models carry Hazardous Locations and intrinsically safe ratings.

SPECIFICATIONS
Accuracy:
   Typical: ±0.1% of output span
   Max: ±0.25% of output span
Hysteresis:
   Typical: ±0.01% of output span
   Max: ±0.10% of output span
Deadband: No effect
Repeatability:
   Typical: ±0.01% of output span
   Max: ±0.10% of output span
Ambient Temperature Effect Zero:
   Typical: ±0.004% of nominal span/°F
   Max: ±0.022% of nominal span/°F
Ambient Temperature Effect Span:
   Typical: 0.013% of calibrated span/°F
   Max: 0.022% of calibrated span/°F
Temperature Effect: ≤0.02%/°F, zero and span effects combined
Operating Temperature Range:
   Buna-N Elastomers: -29 to 71°C (-20 to 160°F)
   Fluorocarbon Elastomers: -18 to 71°C (0 to 160°F)
Storage Temperature Range:
   Buna-N Elastomers: -40 to 93°C (-40 to 200°F)
   Fluorocarbon Elastomers: -26 to 93°C (-15 to 200°F)
Vibration Effects: Less than 0.5% of span per 1 g, 5 to 2000 Hz, 3 g max, 3 axes
Mounting Position Effect: Not measurable
Loop Load, I/P Transducer:
   Less than 10 Vdc drop at 20 mA
   Less than 12 Vdc drop at 50 mA
Supply Voltage, E/P Transducer:
   Intrinsically Safe/Non-Incendive: 9 to 28 Vdc, less than 20 mA
   General Purpose: 9 to 40 Vdc, less than 20 mA
Supply Voltage Effect: No effect
Signal Impedance E/P Transducer: 6000 Ω minimum
RFI/EMI Effect NEMA 4X (IP66): Less than 0.25% of span change in output 10 V/meter, 20 to 1000 MHz (Reference SAMA PML 33.1 to 1978, 2 to abc)
Supply Pressure Sensitivity: No effect
Effective Air Consumption: 0.07 SCFM (2 LPM) maximum
Supply Pressure: 100 psig (6.9 bar) maximum*
* For models with zero output capability maximum supply pressure = 40 psi (2.8 bar) above maximum output, except for 0 to 100 and 0 to 120 psi models that have a maximum supply pressure of 130 psi (9 bar) and 140 psi (9.7 bar) respectively.
Dimensions
   IP510: 102 H x 48 W x 89 mm D (4.01 x 1.88 x 3.5")
   IP511: 144 H x 112 mm W (5.66 x 4.36")
Port Sizes:
   Pneumatic: ¼" FNPT
   Electrical: ½" FNPT
Agency Approvals—All 510 and 511 electropneumatic converters are approved by FM and CSA as intrinsincally safe Class I, Division 1, Groups A, B, C, D hazardous locations. The 511 (NEMA 4X) models are also approved for FM and CSA explosion-proof service: Class I, Division 1 and 2, Groups B, C, D. Dust ignition-proof service: Class II, Division 1 and 2, Groups E, F, G. NEMA 4X units are also suitable for Class III, Division 1 and 2.
Til bestilling(Angiv modelnummer)
Vare nummer/Desc.
Antal 
Beskrivelse
IP510 Models with NEMA 1 (IP00) Enclosure, 4 to 20 mA input
IP510-X15
723,01
Beholdning: 7 uger 
 
Current to pressure converter with 3-15 psi output.
IP510-X27
723,01
Beholdning: 7 uger 
 
Current to pressure converter with 3-27 psi output.
IP510-X30
723,01
Beholdning: 7 uger 
 
Current to pressure converter with 6-30 psi output.
IP510-060
779,07
Beholdning: 7 uger 
 
Current to pressure converter with 0-60 psi output.
IP510-0120
779,07
Beholdning: 1 uge 
 
Current to pressure converter with 0-120 psi output.
EP510 Models with NEMA 1 (IP00) Enclosure, 1 to 5 VDC input
EP510-X15
703,29
Beholdning: 7 uger 
 
Voltage to pressure converter with 3-15 psi output.
EP510-X27
703,29
Beholdning: 7 uger 
 
Voltage to pressure converter with 3-27 psi output.
EP510-X30
703,29
Beholdning: 7 uger 
 
Voltage to pressure converter with 6-30 psi output.
EP510-060
729,57
Beholdning: 7 uger 
 
Voltage to pressure converter with 0-60 psi output.
EP510-0120
733,61
Beholdning: 1 uge 
 
Voltage to pressure converter with 0-120 psi output.
IP511 Models with NEMA 4X (IP66) Enclosure, 4 to 20 mA input
IP511-X15
985,92
Beholdning: 1 uge 
 
Current to pressure converter with 3-15 psi output.
IP511-X27
985,92
Beholdning: 7 uger 
 
Current to pressure converter with 3-27 psi output.
IP511-X30
985,92
Beholdning: 7 uger 
 
Current to pressure converter with 6-30 psi output.
IP511-060
1.072,91
Beholdning: 1 uge 
 
Current to pressure converter with 0-60 psi output.
IP511-0120
1.072,91
Beholdning: 1 uge 
 
Current to pressure converter with 0-120 psi output.
EP511 Models with NEMA 4X (IP66) Enclosure, 1 to 5 VDC input
EP511-X15
959,63
Beholdning: 7 uger 
 
Voltage to pressure converter with 3-15 psi output.
EP511-X27
959,63
Beholdning: 7 uger 
 
Voltage to pressure converter with 3-27 psi output.
EP511-X30
959,63
Beholdning: 7 uger 
 
Voltage to pressure converter with 6-30 psi output.
EP511-060
1.006,00
Beholdning: 7 uger 
 
Voltage to pressure converter with 0-60 psi output.
EP511-0120
1.011,00
Beholdning: 7 uger 
 
Voltage to pressure converter with 0-120 psi output.
All amounts shown in EUR
Ordering Example: (1) IP511-X15 current to pressure converter with 4-20 mA input, 3-15 psi output and NEMA-4X enclosure, €985,92

Delnummerberegner

Build Your Part Number Below
Beskrivelse af tilvalg:


(1) Enclosure Type select from:
IP510 for NEMA 1 (IP00) Enclosure with 4 to 20 mA input
IP511 for NEMA 4X (IP66) Enclosure with 4 to 20 mA input
EP510 for NEMA 1 (IP00) Enclosure with 1 to 5 Vdc input
EP511 for NEMA 4X (IP66) Enclosure with 1 to 5 Vdc input

(2) Specify Output Range select from:
X15 for 3 to 15 psig
X27 for 3 to 27 psig
X30 for 6 to 30 psig
060 for 0 to 60 psig
0120 for 0 to 120 psig

(3) Seal Material select from:
Nothing(leave field blank) for Buna-N seals (standard)
-F for Fluorocarbon seals
Noter: Ikke alle kombinationer er nødvendigvis gyldige. Se specifikationerne for gyldige delnumre.