Cookies på Omegas websteder
Vi anvender cookies på vores websted. Disse cookies er afgørende for, at webstedet kan fungere korrekt.
Hvis du fortsætter uden at ændre dine indstillinger, antager vi, at du gerne vil modtage alle de cookies, der anvendes på dette websted. Du finder flere oplysninger om cookies ved at klikke her
Luk
Kurv  |  Kontakt  | 
GRATIS TELEFON (Kun Danmark. Alle opkald besvares på engelsk) 80 25 14 43
INTERNATIONAL(+45) 80 25 14 43
Layer N Banner

DIN Rail Low Differential Pressure Transducers with 1 to 5 Vdc Output

PX663 Series

DIN Rail Low Differential  Pressure Transducers with 1 to 5 Vdc Output | PX663 Series

975,00 PX663-5BD5V

1 year warranty CE
  • Compact Space-Saving DIN Rail Mountable Design
  • Low Differential Pressure Ranges
  • On-Board Voltage Regulation Allows Use of Low-Cost, Unregulated Power Supply
Tryktransducere - Vis relaterede produkter

Beskrivelse

SPECIFICATIONS
Excitation:
12 to 36 Vdc
Output: 1 to 5 Vdc
Accuracy: ±0.5% FS
Non-Linearity: ±0.4% FS
Hysteresis: ±0.02% FS
Non-Repeatability: ±0.05%
Supply Current: <10 mA
Warm-Up Time: 5 sec max to meet standard specifications from initial power-up
Stability: ±0.5% FS / year
Response Time: 250 ms
Storage Temp.: -40 to 82°C (-40 to 180°F)
Operating temp.: -28 to 82°C (-20 to 180°F) (10 to 95% RH non-condensing)
Compensated Temp.: 2 to 57°C (35 to 135°F)
Zero Temp. Effect: ±0.036% FS/°C (±0.02% FS/°F)
Span Temp. Effect: ±0.036% FS/°C (±0.02% FS/°F)
EMC: CE compliant to EN61326, 1997 ANNEX A harmonized heavy industrial transmitter specification
Proof Pressure: 15 psid
Burst Pressure: 25 psid Max Static Pressure: 25 psi
Mounting Position Effect: 0.1% FS(<0.5" WC: 0.25% FS)
Note: Mounting position effect easily corrected with zero potentiometer
Zero and Span Potentiometers: Front accessible, non-interactive
Zero: ±5% FS
Span: ±3% FS
Pressure Connections: 1/8 NPT female
Weight: 127 grams (4.5 oz)
Enclosure: Glass-filled polycarbonate (UL94 -V-1)
Pressure Media: Clean, dry and non-corrosive gas NOT FOR USE WITH LIQUIDS
Mounting: DIN rail types EN50022, 35 and 45

Models are also available with 4 to 20 mA output. Please see the PX665 for complete details, or contact our Pressure department for more information.
Til bestilling(Angiv modelnummer)
Vare nummer/Desc.
Antal 
Beskrivelse
Uni-Directional Ranges
PX663-0.1D5V
1.206,00
Beholdning: 7 uger 
 
DIN rail mountable differential pressure transducer with 0 to 0.1 inch of water range and 1 to 5 volt output
PX663-0.5D5V
1.121,85
Beholdning: 7 uger 
 
DIN rail mountable differential pressure transducer with 0 to 0.5 inch of water range and 1 to 5 volt output
PX663-1D5V
1.022,00
Beholdning: 7 uger 
 
DIN rail mountable differential pressure transducer with 0 to 1 inch of water range and 1 to 5 volt output
PX663-1.5D5V
1.022,00
Beholdning: 7 uger 
 
DIN rail mountable differential pressure transducer with 0 to 1.5 inch of water range and 1 to 5 volt output
PX663-3D5V
1.022,00
Beholdning: 7 uger 
 
DIN rail mountable differential pressure transducer with 0 to 3 inch of water range and 1 to 5 volt output
PX663-5D5V
1.022,00
Beholdning: 7 uger 
 
DIN rail mountable differential pressure transducer with 0 to 5 inch of water range and 1 to 5 volt output
PX663-10D5V
1.022,00
Beholdning: 7 uger 
 
DIN rail mountable differential pressure transducer with 0 to 10 inch of water range and 1 to 5 volt output
PX663-15D5V
1.022,00
Beholdning: 7 uger 
 
DIN rail mountable differential pressure transducer with 0 to 15 inch of water range and 1 to 5 volt output
PX663-50D5V
1.022,00
Beholdning: 7 uger 
 
DIN rail mountable differential pressure transducer with 0 to 50 inch of water range and 1 to 5 volt output
Bi-Directional Ranges
PX663-0.05BD5V
1.206,00
Beholdning: 7 uger 
 
DIN rail mountable differential pressure transducer with -0.05 to +0.05 inch of water range and 1 to 5 volt output
PX663-1BD5V
1.022,00
Beholdning: 7 uger 
 
DIN rail mountable differential pressure transducer with -1 to +1 inch of water range and 1 to 5 volt output
PX663-2BD5V
1.022,00
Beholdning: 7 uger 
 
DIN rail mountable differential pressure transducer with -2 to +2 inch of water range and 1 to 5 volt output
PX663-5BD5V
975,00
Beholdning: 7 uger 
 
DIN rail mountable differential pressure transducer with -5 to +5 inch of water range and 1 to 5 volt output
All amounts shown in EUR
We noticed you are from the US. Visit your local site for regional offers and live support.