Cookies på Omegas websteder
Vi anvender cookies på vores websted. Disse cookies er afgørende for, at webstedet kan fungere korrekt.
Hvis du fortsætter uden at ændre dine indstillinger, antager vi, at du gerne vil modtage alle de cookies, der anvendes på dette websted. Du finder flere oplysninger om cookies ved at klikke her
Luk
Kurv  |  Kontakt  | 
GRATIS TELEFON (Kun Danmark. Alle opkald besvares på engelsk) 80 25 14 43
INTERNATIONAL(+45) 80 25 14 43
Layer N Banner

Conductivity, Resistivity or TDS Controller

CDCN-961

CDCN-961 Series Conductivity controller | CDCN-961

CDCN-961 Series Conductivity controller

1.418,66 CDCN-961

1 year warranty CE
  • Menu-Driven User Set-up
  • IP65 (NEMA 4X) Enclosure
  • High/Low, and Alarm Relays
  • Dual Backlit LCD
  • Calibration Reminder Via Alarm Relay Setting
  • Isolated 0.4 to 20 mA Retransmission Output
  • RS485 Output
Konduktivitetsinstrumenter - Vis relaterede produkter

Beskrivelse

The CDCN-961 conductance, resistance or total dissolved solids (TDS) controller is designed for in-line monitoring of process solutions and water applications.

The CDCN-961 has a simple menu for easy set-up. Available relays can be configured for control, alarm or as a calibration reminder. The transmitter output can also be set from the keypad, eliminating the need for potentiometer or dip-switch settings. The calibration function automatically recognises the buffer solution resulting in a simple and straight forward system calibration.

Specifications
Conductivity Range:

    0.000 to 3.000, 30.00, 300.0 µS/cm
    0.000 to 3.000, 30.00, 300.0 mS/cm
Resistivity Range:
    0.3 to 30.0 MΩcm
    3 to 300 MΩcm
TDS Range:
    0.000 to 3.000, 30.00, 300.0 ppm
    0.000 to 3.000, 30.00, 300.0 ppt
Resolution:
    0.001/0.01/0.1 µS/cm
    0.001/0.01/0.1 mS/cm
    0.1 MΩcm
Accuracy: ±1% FS
Temperature Range: -0.5 to 130°C (31.1 to 266°F)
Temperature Resolution /Accuracy: 0.1°C/ ±0.5°C
Cell Constant: K = 0.01, 0.1, 1, 10
Line Resistance Compensation: 0.0 to 20.0 Ω
Temperature Sensor: Pt1000
Signal Output/Load: 0/4 to 20 mA/600Ω
Output Interface: RS485
Relay Specification: 3 SPST/250V 1A
Control Hysteresis Band: 0.1 to 10% FS
Frequency of Cleaning Time: 1 to 999 hours 1 to 999 seconds
EMC Standard: EN 50081-1/EN 50082-1
Operation Temperature: -10 to 50°C
Operation Humidity: 10 to 95%
Enclosure: NEMA 4X (IP65)
Dimensions: 100 W x 108 L x 136 Dia mm
Panel Cutout: 93.5 L x 93.5 W mm
Weight: 1650 g
Accessory:
    Conductivity Electrode: K=1.0
    Material: PPS/graphite
    Test Range: 0 to 50.0 mS/cm
    Temperature Range: 0 to 80°C
    Temperature System: Pt1000
    Cable: 5 metres
Til bestilling(Angiv modelnummer)

Andre har købt: Du kan klikke på dette ikon og få vist en liste over produkter, som andre har købt sammen med denne model.

Vare nummer/Desc.
Antal 
Beskrivelse
  
CDCN-961
1.418,66
Beholdning: 5 uger 
 
Conductivity resistivity TDS controller
Acessories
  
CDE-961
616,24
Beholdning: 1 uge 
 
Replacement probe/cell for CDCN-961 controller
Click to expand/minimize a list of what others bought with theCDSA-10
CDSA-10
69,32
Beholdning: 2 uger 
 
10 µmho/cm conductivity solution, 940 ml bottle
Click to expand/minimize a list of what others bought with theCDSA-45
CDSA-45
17,99
Beholdning: 2 uger 
 
45 µS/cm conductivity solution
All amounts shown in EUR
Noter: Comes complete with probe/cell and operator’s manual.
We noticed you are from the US. Visit your local site for regional offers and live support.