Cookies på Omegas websteder Vi anvender cookies på vores websted. Disse cookies er afgørende for, at webstedet kan fungere korrekt. Hvis du fortsætter uden at ændre dine indstillinger, antager vi, at du gerne vil modtage alle de cookies, der anvendes på dette websted. Du finder flere oplysninger om cookies ved at klikke her
GRATIS TELEFON (Kun Danmark. Alle opkald besvares på engelsk)
80 25 14 43
INTERNATIONAL(+45) 80 25 14 43
i-Series 1/32 DIN Programmable Strain/ Process Controllers and Meters with RS-232 & RS-485 Communications Featuring a Totally Programmable Color Display
*For our newest range of controllers with Modbus connectivity, expanded ramp and soak programs, universal inputs, and simple PC set-up, visit our Platinum Series.*
The iS32 series of meter/controllers can measure a wide variety of DC voltage and current outputs for all common load cells, pressure transducers, and most any strain gauge type of transducer. It is the first instrument of its kind, offering a wealth of powerful features and performance in an amazingly compact 1/32 DIN package. The iS32 handles input ranges of 0-100 mV, 0-1 V, 0-10 V, 0-20 mA (4-20 mA). The iS32 is easy to configure and scale to virtually any engineering units using the push buttons on the front panel, or using personal computer with the optional serial communications and free configuration software. The serial communications option includes both RS-232 and RS-485 on one instrument, and the straightforward OMEGA ASCII communications protocol. If Modbus is required, we recommend our latest Platinum controllers - CNPT Series.The iS32 includes built-in excitation for transducers, selectable as 10 V at 100 mA or 5 V at 60 mA. The iS32 features a choice of two optional outputs: Form C SPDT (single pole double throw) mechanical relays, solid state relays, DC pulse, and programmable analog output selectable for either a control function or retransmission of the process value. The iS32 features the iSeries totally programmable color display that can change colors between Green, Amber, and Red at any setpoint or alarm point.
SPECIFICATIONS Input Ranges: 0-100 mV, 0-1 V, 0-10 V, 0-20 mA Isolation: 354 V peak per IEC spacing NMR: 60 dB CMR: 120 dB Input Impedance: 10 MOhms for 100 mV input, 1 MOhm for 1 or 10 V input, 5 Ohms for 20 mA current input Display: 4 digits, 9 segments 10.2 mm (.4") Analog-to-Digital technique: Dual slope Internal A/D Resolution: 15 bits Read rate: 3 / sec Polarity: Automatic Max Error Strain/Process: ±0.03% rdg. Span tempco.: ± 50 ppm / C Step response: 1-2 sec. Warmup to rated accuracy: 30 min. Analog Output (optional): 0-10 V, 4-20 mA, can be used as Retransmission or PID Control. Excitation Voltage: 10 V @ 100 mA, 5 V @ 60 mA (no excitation on models with "C24" or "DC" options) Power: 90-240 Vac 50-400 Hz or 90-375 Vdc, 4 W (optional) 24 Vac 50-400 Hz or 12-36 Vdc, 5 W Dimensions: 25.4 H x 48 W x 127 D mm (1.0 x 1.89 x 5.0") Weight: 127 g (0.28 lb) Approvals: CE per EN50081-1, EN50082-2, EN61010-1
For full product specifications view Specs pdf
Examples of pricing for popular models is referenced in the "To Order" box. Use the "Part Number Builder" below to get pricing for all available models.
† All amounts shown in EUR Noter: Transducer excitation not available on models with serial communications ("-C24") option.
Delnummerberegner
Build Your Part Number Below
Beskrivelse af tilvalg:
(1)
Control Outputs #1 select from: 2 for Solid State Relay/1 A at 120/240 Vac continuous 3 for SPDT Relay 4 for Pulsed 10 Vdc at 20 mA 5 for Analogue Output 0 to 10 Vdc or 4-20 mA
(2)
Control Outputs #2 select from: 2 for Solid State Relay/1 A at 120/240 Vac continuous 3 for Relay SPDT 3A at 120/3 A at 240 Vac 4 for Pulsed Driver 10 Vdc at 20 mA /for use with external SSR
(3)
Serial Communications select from: Nothing(leave field blank) for Standard Unit -C24 for Isolated RS-232 and RS-485 300 to 19.2 k baud
(4)
Power Supply select from: Nothing(leave field blank) for Standard Power (90 to 240 Vac/dc @ 50 to 400 Hz) -DC for Low Voltage Power (24 Vac or 12 to 36 Vdc)
Noter: Ikke alle kombinationer er nødvendigvis gyldige. Se specifikationerne for gyldige delnumre.