Cookies på Omegas websteder
Vi anvender cookies på vores websted. Disse cookies er afgørende for, at webstedet kan fungere korrekt.
Hvis du fortsætter uden at ændre dine indstillinger, antager vi, at du gerne vil modtage alle de cookies, der anvendes på dette websted. Du finder flere oplysninger om cookies ved at klikke her
Luk
Kurv  |  Kontakt  | 
GRATIS TELEFON (Kun Danmark. Alle opkald besvares på engelsk) 80 25 14 43
INTERNATIONAL(+45) 80 25 14 43
Layer N Banner

Signalbetingere for procesinput

DRF-PR

Signalbetingere for procesinput | DRF-PR

Signalbetingere for procesinput

231,33 DRF-PR-230VAC-0/10VDC-4/20

1 year warranty CE
  • Processignaler op til 10 VDC
    og op til 50 mA
  • Nøjagtighed 0,2 %
  • Reaktionstid <70 msek.
  • Excitationsspænding til transducere +15 VDC (20 mA)
  • Galvanisk isolering mellem input, output og effekt
Signalindlæringsenheder - Vis relaterede produkter

Beskrivelse

The DRF series DIN rail signal conditioners are designed to accept a broad range of input signals, such as ac and dc voltage and current, frequency, temperature (thermocouple and RTD), and process transducers, and provide standard process outputs of either 4 to 20 mA, or 0 to 10 Vdc. The DRF series feature a modern housing design, that is easily mounted on standard 35 mm DIN rails. Connections are safely and securely made through pluggable screw terminal connectors, with input and output connections on the opposite sides of the module.

The DRF-PR signal conditioner accepts a dc process signal input and provides an isolated 0 to 10 Vdc or 4 to 20 mA output. Models are available with three different power options, 24 Vdc, 115 Vac and 230 Vac.

The DRF-PR are ideally suited for industrial applications. They feature galvanic isolation between input, output and power up to 3500 Veff (model specific). Module response time is 70 ms or less.

Range Code Table
Range CodeRange
0/5MA0 to 5 mA
0/50MA0 to 50 mA
0/20MA0 to 20 mA
4/20MA4 to 20 mA
0/1VDC0 to 1 Vdc
0/10VDC0 to 10 Vdc


SPECIFICATIONS

Accuracy: <0.2% full scale
Linearity: <<0.1% full scale
Thermal Drift: 150 ppm/°C typical (max <200ppm/°C)
Response Time: <70 mS (90% of signal)at 20 Hz -3 dB
Impedance and Overvoltage:
RangeImpedanceOvervoltage(max)
4 to 20mA50Ω3.5 Vdc
0 to 20mA50Ω3.5 Vdc
0 to 50mA20Ω2.5 Vdc
0 to 5mA20Ω2.5 Vdc
0 to 10Vdc5MΩ150 Vdc
0 to 1Vdc1MΩ15 Vdc


Power: 24 Vdc ±10%, 230 Vac ±10% 50/60 Hz, 115 Vac ±10% 50/60 Hz
Power Consumption: <3.8 VA
 

Output: 4 to 20 mA and 0 to 10 Vdc
Maximum Voltage Output: 11 Vdc approx.
Minimum Voltage Output: -1 Vdc approx.
Minimum Load Resistance (Voltage): >1 KΩ Maximum Current Output: 22 mA approx.
Maximum Current Output: -1.5 mA approx.
Maximum Load Resistance (current): >400 Ω

Vexc Output for Transducers:+15 Vdc ±10% (22 mA max.)

Electrical Connections: Plug-in screw terminals
Protection: IP-30

MECHANICAL DIMENSIONS
Weight:
(DC Powered Models): 120 g (4.2 oz)
(AC Powered Models): 200 g (7 oz)
Dimensions:
(DC Powered models):
110 H x 22.5 W x 93 mm D (4.3 x 0.9 x 3.7")
(AC Powered models):
110 H x 37 W x 93 mm D (4.3 x 1.46 x 3.7")
Operating Temperature: 0 to 60°C (32 to 140°F)
Storage Temperature: -20 to 70°C (-4 to 158°F)
Til bestilling(Angiv modelnummer)
Vare nummer/Desc.
Antal 
Beskrivelse
Below are examples of popular models. See the Part Number Builder to order any available model.
DRF-PR-24VDC-0/10VDC-4/20
Kontakt salgsafdelingen    
Beholdning: 
 
 
Process signal conditioner with 0 to 10V input and 4 to 20 mA output, 24 Vdc power
DRF-PR-230VAC-0/10VDC-4/20
231,33
Beholdning: 7 uger 
 
Process signal conditioner with 0 to 10V input and 4 to 20 mA output, 230Vac power
DRF-PR-115VAC-0/10VDC-4/20
231,33
Beholdning: 1 uge 
 
Process signal conditioner with 0 to 10V input and 4 to 20 mA output, 115 Vac power
DRF-PR-230VAC-0/10VDC-0/10
231,33
Beholdning: 7 uger 
 
Process signal conditioner with 0 to 10V input and 0 to 10Vdc output, 230 Vac power
DRF-PR-115VAC-0/10VDC-0/10
231,33
Beholdning: 1 uge 
 
Process signal conditioner with 0 to 10V input and 0 to 10Vdc output, 115 Vac power
All amounts shown in EUR

Delnummerberegner

Build Your Part Number Below
Beskrivelse af tilvalg:


(1) Power select from:
24VDC for 24Vdc power
115VAC for 115Vac power
230VAC for 230Vac power

(2) Input Signal select from:
0/5MA for 0 to 5 mA
0/50MA for 0 to 50 mA
0/20MA for 0 to 20mA
4/20MA for 4 to 20mA
0/1VDC for 0 to 1 Vdc
0/10VDC for 0 to 10 Vdc

(3) Output select from:
4/20 for 4 to 20mA
0/10 for 0 to 10Vdc
Noter: Ikke alle kombinationer er nødvendigvis gyldige. Se specifikationerne for gyldige delnumre.
We noticed you are from the US. Visit your local site for regional offers and live support.