Cookies på Omegas websteder Vi anvender cookies på vores websted. Disse cookies er afgørende for, at webstedet kan fungere korrekt. Hvis du fortsætter uden at ændre dine indstillinger, antager vi, at du gerne vil modtage alle de cookies, der anvendes på dette websted. Du finder flere oplysninger om cookies ved at klikke her
Brand New DRST-BG MV Signal Transmitter converts bipolar mV signals from transducers supplied directly by the device to standard current/voltage signals.
Application
DRST-BG is suitable for load cell application as well as other
applications such as tank filling and draining, weighing with a
taring function, measurement of cable tensile force, level
control, signal conversion/amplification. Advanced Features
A multifunction user interface consisting of three push buttons
and a 3-digit LED display for programming. Technical Characteristics
• Front error LED.
• The analog input can be programmed for voltage in the range -40 to 100 m Vdc.
• The digital signal can be selected as either NPN or PNP. Taring can either be by way of the digital input or from the front interface.
• The analog output can be programmed to current in the range 0 to 20 mA or voltage in the range
• Short circuit protected transducer supply which can be
programmed to 5 to 13 Vdc from the front.
• Sense input (with transducer supply used) for compensation for cable resistance to the transducer.
• Mounting for a standard 11-pole socket which can be adapted for DIN rail or plate.
Mechanical Specifications Dimensions (HxWxD): 80.5 x 35.5 x 84.5 mm (D is without pins) Weight Approx: 130 g
Common Specifications Supply Voltage: 19.2 to 28.8 Vdc Max. Required Power: 7.2 W Internal Power Dissipation: 2.2 W Response Time (Programmable): 0.06 to 999 s Signal/Noise Ratio: Min. 60 dB Updating Time: 20 ms Signal Dynamics, Input: 17 bit Signal Dynamics, Output: 16 bit Effect of Supply Voltage Change: < ±0.002% of span/%V Temperature Coefficient: < ±0.01% of span/°C Linearity Error: < 0.1% of span Auxiliary Voltage: Transducer Supply: 5 to 13 Vdc Load (Max.): 230 mA EMC Immunity Influence: < ±0.5% of span
Input Specifications Common Input Specifications Max. Offset: 70% of selec. max. value Voltage input Measurement Range: -40 to 100 mV Min. Measurement Range (Span): 10 mV Input Resistance: > 10 MO Overrange: 0 to 999% of selected measurement range NPN, Digital Input: Pull up 24 Vdc / 6.9 mA PNP, Digital Input: Pull down 0 Vdc/6.9 mA Trig Level Low, NPN/PNP: < 6 Vdc Trig Level High, NPN/PNP: > 10.5 Vdc Pulse Length: > 30 ms
Output Specifications Current Output Signal Range: 0 to 20 mA Min. Signal Range: 5 mA Load (@ Current Output): = 600 Ω Load Stability:= 0.01% of span/100 Ω Current Limit: < 23 mA Voltage Output Through Internal shunt: See manual for details Of Span: = of the presently selected range