Economical Ball Bearing Turbine Flowmeters With 37 Degree Flare Fittings

FTB-200

Economical Ball Bearing Turbine Flowmeters With 37 Degree Flare Fittings | FTB-200

Se Alt Models Below

  • ±½% of Reading Accuracy
  • Ball Bearing Design for Economy
  • Deflector Cones Stabilize Low Mass Rotor for Increased Bearing Life
  • NIST Traceable Calibration Certificate Included for Water
Vandmålere - Vis relaterede produkter

Beskrivelse

Click on this link if you need more information about a Flow meter.

OMEGA™ FTB-201 Series turbine meters have male flared-end fittings for easy connections. They are built to meet the performance requirements of MS 33656, though they do not carry a military specification. These units come with a mating 2-wire connector and can be supplied with the integrally mounted signal conditioners, shown in the to-order table below, to provide 4 to 20 mA, 0 to 5V, and factored pulse outputs.

37° Flare Installation Kits
Proper application of a turbine Installation kits for turbine meters with 37° flare end fittings consist of two lengths of stainless steel tubing cut to a length appropriate for the upstream and downstream straight pipe runs and flared at one end. Mating sleeves and nuts are included. The kits can be conveniently butt-welded into the piping system. Flow straightening sections may be provided with the installation kit. These kits are available in tubing sizes from ½ to 2".

These turbine meters are intended for clean fluid service only; where there is any doubt concerning possible particulate impurities in the process fluid, strainers are recommended. In addition, when using these units for fluids with viscosities other than 1 centistoke, special calibrations and universal viscosity curves are available – consult OMEGA’s sales department.

Ranges
Model
Linear Flow
Range (litres/min)
37° Flare Fittings
Max. Op.
Pressure (Barg)
Length (mm)
Nom. K Factor
Pulses/litre
FTB-201
1.3 to 13.2
¾-16 UNF-3A
344
62
3430
FTB-202
2.8 to 28.4
¾-16 UNF-3A
344
62
2640
FTB-203
4.7 to 36
¾-16 UNF-3A
344
62
1580
FTB-204
6.6 to 60
7/8-14 UNF-3A
344
70
1080
FTB-205
9.5 to 110
1 1/16-12 UNF-3A
344
83
580
FTB-206
15 to 227
1 5/16 -12 UNF-3A
241
89
170
FTB-207
23 to 352
1 5/8 -12 UNF-3A
206
99
110
FTB-208
30 to 492
1 7/8 -12 UNF-3A
155
111
60
FTB-209
57 to 850
2½-12 UNF-3A
120
121
32


Specifications
Accuracy: ±0.5% of reading
Repeatability: ±0.1% of reading
Temperature Range: -268 to 232°C
Maximum Intermittent Overrange: 150% of maximum range
Materials of Construction:
   Body: 304 SS
   Rotor: 17-4 PH SS
   Bearings: 440C SS
Installation Kits: 340 SS, 1.7 mm thick
Electrical: Two-wire connector included
Max Pressure Drop: 0.34 bar

Til bestilling(Angiv modelnummer)
Vare nummer/Desc.
Antal 
Beskrivelse
FTB-201
1.628,00
Beholdning: 8 uger 
 
Linear range water 1.3 to 13.2 l/m; End conections: 3/4-16UNF-3A liquid turbine flowmeters
FTB-202
1.628,00
Beholdning: 8 uger 
 
Linear range water 2.8 to 28.5 l/m; End conections: 3/4-16UNF-3A liquid turbine flowmeters
FTB-203
2.098,83
Beholdning: 8 uger 
 
Linear range water 4.7 to 36 l/m. End conections: 3/4-16UNF-3A liquid turbine flowmeters
FTB-204
1.628,00
Beholdning: 9 uger 
 
Linear range water 6.6 to 60 l/m. End conections: 7/8-14 UNF-3A liquid turbine flowmeters
FTB-205
1.628,00
Beholdning: 11 uger 
 
Linear range water 9.5 to 110 l/m. End conections: 1 1/16-12 UNF-3A liquid turbine flowmeters
FTB-206
1.802,00
Beholdning: 8 uger 
 
Linear range water 15 to 227 l/m. End conections: 1 5/16-12 UNF-3A liquid turbine flowmeters
FTB-207
1.917,00
Beholdning: 9 uger 
 
Linear range water 23 to 352 l/m. End conections: 1 5/8 -12 UNF-3A liquid turbine flowmeters
FTB-208
1.969,00
Beholdning: 9 uger 
 
Linear range water 30 to 492 l/m. End conections: 1 7/8 -12 UNF-3A liquid turbine flowmeters
FTB-209
2.320,00
Beholdning: 9 uger 
 
Linear range water 57 to 850 l/m. End conections: 2 1/2 -12 UNF-3A liquid turbine flowmeters
Signal conditioners. Order as a system if purchased with a turbine meter. Eg: SYS/FTB-201/FLSC-18B. Use table below to order
FLSC-18B
Kontakt salgsafdelingen    
Beholdning: 
 
 
Signal Conditioner 4-20mA output requires 8-40V dc
FLSC-34
Kontakt salgsafdelingen    
Beholdning: 
 
 
Signal Conditioner 4-20mA output requires 115 V ac
FLSC-28
Kontakt salgsafdelingen    
Beholdning: 
 
 
Signal Conditioner 0-5 V output requires 8-40V dc
FLSC-35B
Kontakt salgsafdelingen    
Beholdning: 
 
 
Signal Conditioner 0-5 V output requires 115 V ac
FLSC-51
Kontakt salgsafdelingen    
Beholdning: 
 
 
Signal Conditioner Square Wave output requires 8-35 V dc
Installation Kits
FTB-K3
€427,16
Beholdning: 8 uger 
 
37 Degree Flare Installation Kits for FTB-201, FTB-202, FTB-203. 10" Inlet/5" Outlet Length
FTB-K4
€487,45
Beholdning: 1 uge 
 
37 Degree Flare Installation Kit for FTB-204. 10" Inlet/5" Outlet Length
FTB-K5
€562,63
Beholdning: 8 uger 
 
37 Degree Flare Installation Kit for FTB-205. 10" Inlet/5" Outlet Length
FTB-K6
€598,01
Beholdning: 8 uger 
 
37 Degree Flare Installation Kit for FTB-206. 10" Inlet/5" Outlet Length
FTB-K7
€770,77
Beholdning: 8 uger 
 
37 Degree Flare Installation Kit for FTB-207. 14" Inlet/6" Outlet Length
FTB-K8
€891,99
Beholdning: 8 uger 
 
37 Degree Flare Installation Kit for FTB-208. 17" Inlet/8" Outlet Length
FTB-K9
€1.564,00
Beholdning: 8 uger 
 
37 Degree Flare Installation Kit for FTB-209. 21" Inlet/9" Outlet Length

Bestil efter Vare nummer

Vare nummer
Antal 
Vare nummer
Antal 


All amounts shown in EUR
Noter: If an integral signal conditioner is required please order as a system. Omega will scale the signal conditioner to the turbine meter.
Example: SYS/FTB-201/FLSC-18B, scaled system includes: Signal Conditioner, Enclosure, Turbine Meter and Fitting. No additional charge- just add the flowmeter and signal conditioner prices together. Use the table below to order
We noticed you are from the US. Visit your local site for regional offers and live support.