Thermocouple Probe - Molded Transition Joint Probes with PFA Insulated Lead Wire

(*)TSS Series

Thermocouple Probe | Molded Thermocouple Transition Joint Probes | Insulated Lead Wire | (*)TSS Series

59,50 KTXL-14U-12

  • Probes Molded in House to ensure Quality and Performance
  • 304SS and Inconel® 600 Sheaths
  • 1 m (40 in.) PFA-Insulated Lead Wire with Stripped Leads
  • Manufactureed with OMEGACLAD™ Compacted Mineral Insulation Cable for Long-Lasting, Low-Drift Performance
  • Lead and Transition Rated to 260°C (500°F)
Termokoblere - Vis relaterede produkter

Beskrivelse

For long life, drift-free operation, choose Super OMEGACLAD™ XL mineral insulated thermocouple cable and our rugged transition joint probes, which are available in Type K and N calibrations.
Calibration
ANSI Code
Sheath
Materials
Sheath Dia.
mm (in.)
T/C Junction
Upper Temp.
°C (°F)
Model Number
(See notes, below)
K
Cromega®-
AL
304SS 1.59 (1/16)
3.18 (1/8)
4.78 (3/16)
6.35 (1/4)
899 (1650)
899 (1650)
899 (1650)
899 (1650)
KTSS-116(*)-(**)
KTSS-18(*)-(**)
KTSS-316(*)-(**)
KTSS-14(*)-(**)
Inconel®
600
1.59 (1/16)
3.18 (1/8)
4.78 (3/16)
6.35 (1/4)
921 (1690)
1071 (1960)
1149 (2100)
1149 (2100)
KTIN-116(*)-(**)
KTIN-18(*)-(**)
KTIN-316(*)-(**)
KTIN-14(*)-(**)
Super
OMEGACLAD™
XL
1.59 (1/16)
3.18 (1/8)
4.78 (3/16)
6.35 (1/4)
1038 (1900)
1149 (2100)
1204 (2200)
1204 (2200)
KTXL-116(*)-(**)
KTXL-18(*)-(**)
KTXL-316(*)-(**)
KTXL-14(*)-(**)
J
Iron-
Constantan
304SS 1.59 (1/16)
3.18 (1/8)
4.78 (3/16)
6.35 (1/4)
441 (825)
521 (970)
621 (1150)
721 (1330)
JTSS-116(*)-(**)
JTSS-18(*)-(**)
JTSS-316(*)-(**)
JTSS-14(*)-(**)
T
Copper-
Constantan
304SS 1.59 (1/16)
3.18 (1/8)
4.78 (3/16)
6.35 (1/4)
260 (500)
316 (600)
371 (700)
371 (700)
TTSS-116(*)-(**)
TTSS-18(*)-(**)
TTSS-316(*)-(**)
TTSS-14(*)-(**)
Notes: *Specify Junction: (G)rounded, (E)xposed or or (U)ngrounded.
**Specify length in inches: 6 for 150 mm (6 in.), 12 for 300 mm (12 in.), or 18 for 450 mm (18 in.).
Super OMEGACLAD™ XL probes (highlighted in yellow) are also available in N calibration; substitute NT for KT in Model Number. Some Type E devices are also available. See ordering examples below and contact Sales for moe info.
Til bestilling(Angiv modelnummer)
Vare nummer/Desc.
Antal 
Beskrivelse
KTXL-116U-12
56,23
Beholdning: 4 uger 
 
Type K Molded Transition Joint Probe with Super OMEGACLAD™ XL 1/16 in. (1.5 mm) dia. sheath, ungrounded junction, 12 in. (300 mm) length.
KTSS-316G-12
39,96
Beholdning: 4 uger 
 
Type K Molded Transition Joint Probe with 304 SS 3/16 in. (4.5 mm) dia. sheath, ungrounded junction, 12 in. (300 mm) length.
KTIN-14U-12
43,12
Beholdning: 1 uge 
 
Type K Molded Transition Joint Probe with Inconel® 1/4 in. (6 mm) dia. sheath, ungrounded junction, 12 in. (300 mm) length.
JTSS-18G-12
41,43
Beholdning: 4 uger 
 
Type J Molded Transition Joint Probe with 304SS 1/8 in. (3 mm) dia. sheath, ungrounded junction, 12 in. (300 mm) length.
ETSS-116U-12
48,91
Beholdning: 4 uger 
 
Type E Molded Transition Joint Probe with 304SS 1/16 in. (1.5 mm) dia. sheath, ungrounded junction, 12 in. (300 mm) length.
TTSS-14U-18
44,21
Beholdning: 4 uger 
 
Type T Molded Transition Joint Probe with 304SS 1/4 in. (6 mm) dia. sheath, ungrounded junction, 18 in. (450 mm) length.

Bestil efter Vare nummer

Vare nummer
Antal 
Vare nummer
Antal 


All amounts shown in EUR
Noter: For extended lead wire beyond 1 m, add $1 per foot (300 mm). Contact Sales or see the Spec Sheet for prices on additional lengths of MI cable.
Prices for 6 and 12 in. (150 and 300 mm) probes are the same.
(OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)

Delnummerberegner

Build Your Part Number Below
Beskrivelse af tilvalg:


(1) Thermocouple Type select from:
ET for Type E
KT for Type K
JT for Type J
TT for Type T
NT for Type N

(2) Sheath Material select from:
SS for 304 Stainless Steel
IN for Inconel® 600
XL for Super OMEGACLAD™ XL

(3) Sheath Diameter select from:
116 for 1/16 in. (1.5 mm)
18 for 1/8 in. (3 mm)
316 for 3/16 in. (4.5 mm)
14 for 1/4 in. (6 mm)

(4) Junction Type select from:
U for Ungrounded
G for Grounded
E for Exposed

(5) Sheath Length select from:
6 for 6 in. (150 mm)
12 for 12 in. (300 mm)
18 for 18 in. (450 mm)
Noter: Ikke alle kombinationer er nødvendigvis gyldige. Se specifikationerne for gyldige delnumre.