Datalogger til impulsinput

OM-CP-PULSE101A

Datalogger til impulsinput | OM-CP-PULSE101A

Datalogger til impulsinput

118,31 OM-CP-PULSE101A

5 year warranty CE
  • 10 års batterilevetid
  • Impulsfrekvens 10 KHz
  • Flerdobbelt start/stop-funktion
  • Ultrahøj downloadhastighed
  • Hukommelse: 500.000 aflæsninger
  • Hukommelses-wraparound
  • Indikator for batteritid
  • Adgangskodebeskyttelse som ekstraudstyr
  • Realtidsdrift
Dataloggere - Vis relaterede produkter

Beskrivelse

The OM-CP-PULSE101A is a low-cost recording device that will sense a pulse input or contact closure from external sources such as transducers or pulse initiators (gas, water, and electric meters) and transform those inputs into engineering units. In addition, this data logger allows the user to store user defined units such as gallons/min into the device as well as scale factors and offset values. This enables the user to easily linearize and scale any transducer that provides a pulse or contact closure output to any user required units automatically.

Once activated the data logger senses and records the number of pulses/contact closures that occur within adjacent “time bin” periods. The bin period is selectable from 1 second to over 24 hours. At the end of each bin period, the total number of pulses/counts within the bin period is recorded. The data logger then starts another bin period and continues until either the memory is full or the test period has ended. Its real time clock ensures that all data is time and date stamped. This is ideal for recording events.

The storage medium is non-volatile solid state memory, providing maximum data security even if the battery becomes discharged. Its small size allows it to fit almost anywhere. Data retrieval is simple. Plug it into an empty COM port and our easy-to-use software does the rest. The software converts your PC into a real time strip chart recorder. Data can be printed in graphical or tabular format and can be exported to a text or Microsoft Excel file.

Specifications
Input Connection:
Removable screw terminal
Maximum Pulse Rate: 10 KHz
Input Range: 0 to 30 Vdc continuous
Input Low: <0.4V
Input High: >2.8V
Internal Weak Pull-Up: <60 µA
Input Impedance: >60 kΩ
Minimum Pulse Width/Contact Closure Duration: ≥10 microseconds
Reading Rate: 1 reading every second to 1 every 24 hours
Start Modes:
Immediate start
Delay start up to 18 months
Multiple pushbutton start/stop
Multiple Start/Stop Mode: Start and stop the device multiple times without having to download data or communicate with a PC
Multiple Start/Stop Mode Activation: To start the device press and hold the pushbutton for 5 seconds, the device has started logging; to stop the device press and hold the pushbutton for 5 seconds while the device is logging, the device has stopped logging
Memory: 500,000 readings; software configurable memory wrap 250,000 readings in multiple start/stop mode
Memory Wrap Around: Yes (software selectable)
Real-Time Recording: The device may be used with PC to monitor and record data in real-time
LED Functionality:
  Green LED Blinks: 10 second rate to indicate logging; 15 second rate to indicate delay start mode
  Red LED Blinks: 10 second rate to indicate low battery and/or full memory; 1 second rate to indicate   an alarm condition
Password Protection: An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password.
Engineering Units: Native measurement units can be scaled to display measurement units of another type. This is useful when monitoring outputs from different types of sensors such as flow rate, wind speed and more.
Battery Type: 3.6V lithium battery (included); user replaceable
Battery Life: 10 years typical, dependent upon frequency and duty cycle (see chart)
Time Accuracy: ±1 minute/month at 20ºC (68ºF), stand alone data logging
Computer Interface: USB (interface cable required); 115,200 baud
Software: XP SP3/Vista and 7 (32 and 64-bit)
Software: XP SP3/Vista/Windows 7 (32 and 64-bit)
Dimensions:
  Data Logger: 36 H x 56 W x 16 mm D (1.4 x 2.2 x 0.6")
  Waterbox Enclosure: 74 H x 148 W x 39 mm D (2.9 x 5.8 x 1.5")
Weight: 24 g (0.9 oz)
Materials:
  Data Logger: ABS Plastic
  Waterbox Enclosure: Black anodized aluminum
Til bestilling(Angiv modelnummer)

Andre har købt: Du kan klikke på dette ikon og få vist en liste over produkter, som andre har købt sammen med denne model.

Vare nummer/Desc.
Antal 
Beskrivelse
Click to expand/minimize a list of what others bought with theOM-CP-PULSE101A
OM-CP-PULSE101A
118,31
Beholdning: På lager
 
Pulse input data logger with USB interface
Click to expand/minimize a list of what others bought with theOM-CP-IFC200
OM-CP-IFC200
168,91
Beholdning: På lager
 
Windows software and 1.8 m (6') USB interface cable
Click to expand/minimize a list of what others bought with theOM-CP-BAT105
OM-CP-BAT105
24,16
Beholdning: På lager
 
Replacement 3.6V lithium battery
Click to expand/minimize a list of what others bought with theOM-CP-WATERBOX101A
OM-CP-WATERBOX101A
55,50
Beholdning: På lager
 
Weatherproof enclosure for data logger
All amounts shown in EUR
Noter: Comes complete with 3.6V lithium battery. Operator’s manual and USB interface cable are included with the OM-CP-IFC200 Windows software (required to operate the data logger, sold separately).

Produkthåndbøger:

Download OM-CP Series - Data Logger Quickstart Guide
Download OM-CP Series - Data Logger and Software User Guide

Software:

Download OM-CP Data Logging Software
Download OM-CP software