€866,16 OM-DAQ-USB-2401
Beskrivelse
The OM-DAQ-USB-2401 is a USB 2.0 full speed thermocouple/voltage input data acquisition module (fully compatible with both USB 1.1 and USB 2.0 ports). This stand-alone module draws power from the host PC's USB port to operate. An external power supply is also included, to allow use with non-powered USB hubs. All configurable options (including individual channel input type and range) are software programmable.
The OM-DAQ-USB-2401 is user programmable for thermocouple types J/K/T/E/R/S/B/N and voltage input ranges from ±30 mV to ±10V full scale.
The compact, modular
packaging ensures ease of use in a variety of applications. Units
can be DIN rail or wall mounted with
the included hardware and also have rubber feet for bench-top use. All analogue input channels can be measured sequentially at about 1 ms per channel. A total of 1000 samples per second can be taken, divided across all active channels.*
![]() |
Omega's DAQ Central software for real-time display and data logging is included DAQ Central software allows charting, data logging, file storage and virtual instrument viewing (digital meters, dial gauges, bar graphs) of data in real time. No programming is required - simply point, click, and drag desired display options to create a virtual display screen. Additionally, for those users who would like to design and develop their own custom applications, the software suite includes a .NET driver for C#, Visual Basic and Visual C++. |
|||||||||||||||
Specifications Isolation: 500V from PC Excitation Output Voltage: 12 Vdc regulated, max total current output 67 mA Input Voltage Range: Software programmable on a per-channel basis differential/single-ended
TC Input Ranges Type J: -18 to 1200°C (0 to 2192°F) Type K: -129 to 1372°C (-200 to 2502°F) Type T: -101 to 400°C (-150 to 752°F) Type E: -184 to 1000°C (-300 to 1832°F) Type R: 204 to 1768°C (400 to 3214°F) Type S: 204 to 1768°C (400 to 3214°F) Type B: 538 to 1820°C (1000 to 3308°F) Type N: -129 to 1300°C (-200 to 2372°F) Cold Junction Compensation Accuracy: ±1.0°C |
Thermocouple Accuracy: In very slow mode, 24 bit resolution J = ±1.1°C K = ±1.2°C T = ±1.1°C E = ±1.0°C R = ±2.5°C S = ±2.6°C B = ±3.3°C N = ±1.5°C Analogue Input Accuracy: Differential Input: In very slow mode, 0.015% of reading +0.004% of range +10uV (exclusive of noise) Single-End Input: In very slow mode, 0.05% of reading +0.01% of range +50uV (exclusive of noise) USB Device Type: USB 2.0 (full-speed). Compatible with USB 1.1 and 2.0 Mounting: Rubber feet for benchtop use. DIN rail and wall mounting brackets included. Open Thermocouple Detect: Automatically enabled when a channel is configured for a thermocouple sensor Power Requirements: Powered direct from USB port, max 500 mA, or from external 7.5 to 12 Vdc adapter (supplied) Operating Temperature: 0 to 50°C, 0 to 95% RH non-condensing Storage Temperature: -40 to 85°C Weight: 0.23 kg Dimensions: 107 W x 128 L x 39 mm H |
Produkthåndbøger: