Thermocouple Profile Probes Made from High-Accuracy Special Limits-of-Error Wire (SLE)

PP3, PP6, and PP10 Series

Multipoint Thermocouple Probes for temperature profiles | PP3, PP6, and PP10 Series

Multipoint Thermocouple Probes for temperature profiles

625,70 PP6-36-K-G-18

  • Multipoint Thermocouple Probes with 3, 6, & 10 Sensing Points
  • 18 and 36" Lengths
  • 36" Long, 24 AWG Stranded Individual Leads
  • 3/16" Diameter 316SS Sheaths
  • J, K, T, and E Calibrations
  • Individual Thermocouple Terminations Labeled for Easy Identification
  • Up to 650°C (1200°F) Maximum Temperature Rating
Termokoblere - Vis relaterede produkter

Beskrivelse

STANDARD VERSIONS: OMEGA now stocks several different versions of Multipoint Thermocouple Probes probes for off-the-shelf delivery. Stocked probes come in a variety of lengths, calibrations, and sensing point configurations. CUSTOM VERSIONS: Multipoint Profile Probes designed to your exact needs are, of course, also available. Pick your own spacing between temperature points, number of sensing points, diameter, sheath material, thermocouple calibration and termination style. NOTE:Smaller diameter Profile Probes mean faster response times. The minimum diameter of profile probe is dependent upon maximum temperature you want monitor and number of sensing points desired. Sketch your probe on the downloadable PDF page under related links at the bottom of this page and fax it to OMEGA’s Custom Engineering Department

All units are terminated with a metal transition fitting going to 36 inches of PFA wire.
Til bestilling(Angiv modelnummer)
Vare nummer/Desc.
Antal 
Beskrivelse
PP3-36-K-U-18
488,15
Beholdning: 6 uger 
 
K type, ungrounded, multipoint Thermocouple, Sensing Length: 18", Space between points: 4.5", Number of sensing points: 3
PP3-36-K-G-18
478,74
Beholdning: 6 uger 
 
K type, grounded, multipoint Thermocouple, Sensing Length: 18", Space between points: 4.5", Number of sensing points: 3
PP3-36-K-U-36
500,83
Beholdning: 6 uger 
 
K type ungrounded multipoint Thermocouple, Sensing Length: 36", Space between points: 9", Number of sensing points: 3
PP3-36-K-G-36
492,41
Beholdning: 6 uger 
 
K type grounded multipoint Thermocouple, Sensing Length: 36", Space between points: 9", Number of sensing points: 3
PP6-36-K-U-18
561,73
Beholdning: 6 uger 
 
K type ungrounded multipoint Thermocouple, Sensing Length: 18", Space between points: 1.75", Number of sensing points: 6
PP10-36-K-U-18
746,59
Beholdning: 6 uger 
 
K type ungrounded multipoint Thermocouple, Sensing Length: 18", Space between points: 1.25", Number of sensing points: 10
PP3-36-J-U-18
478,74
Beholdning: 6 uger 
 
J type ungrounded multipoint Thermocouple, Sensing Length: 18", Space between points: 4.5", Number of sensing points: 3
PP10-36-J-U-18
861,70
Beholdning: 6 uger 
 
J type ungrounded multipoint Thermocouple, Sensing Length: 18", Space between points: 1.25", Number of sensing points: 10
PP3-36-J-U-36
500,83
Beholdning: 6 uger 
 
J type ungrounded multipoint Thermocouple, Sensing Length: 36", Space between points: 9", Number of sensing points: 3
PP3-36-J-G-36
500,83
Beholdning: 6 uger 
 
J type grounded multipoint Thermocouple, Sensing Length: 36", Space between points: 9", Number of sensing points: 3
PP6-36-K-U-18
561,73
Beholdning: 6 uger 
 
J type ungrounded multipoint Thermocouple, Sensing Length: 18", Space between points: 1.75", Number of sensing points: 6
PP6-36-K-G-18
625,70
Beholdning: 6 uger 
 
J type grounded multipoint Thermocouple, Sensing Length: 18", Space between points: 1.75", Number of sensing points: 6
All amounts shown in EUR
Noter: NOTE: Maximum Continuous Temperatures: J, T: 500°F (260°C); E: 570°F (300°C); K: 1200°F (650°C)
† First point always at probe tip.

Delnummerberegner

Build Your Part Number Below
Beskrivelse af tilvalg:


(1) Number of Sensing Points select from:
PP3-36 for 3 Sensing Points
PP6-36 for 6 Sensing Points
PP10-36 for 10 Sensing Points

(2) Thermocouple Type select from:
J for J Thermocouple
K for K Thermocouple
T for T Thermocouple
E for E Thermocouple

(3) Junction Style select from:
U for Ungrounded
G for Grounded

(4) Sensing Length select from:
18 for 18 Inches
36 for 36 Inches
Noter: Ikke alle kombinationer er nødvendigvis gyldige. Se specifikationerne for gyldige delnumre.