RTD Probe with Insulated Wire and Shrink-Tube Support

PR-10

RTD Probe with Insulated Wire and Shrink-Tube Support
 | PR-10

RTD Probe with Insulated Wire and Shrink-Tube Support

144,75 PR-10E-3-100-1/8-6

  • Low temperature range: -50 to 250°C (-58 to 482°F)
  • High temperature range: -50 to 450°C (-58 to 842°F)
  • Extreme temperature range: -200 to 600°C (-328 to 1112°F)
  • Class A accuracy conforming to IEC 60751
  • Standard probe lengths: 2, 3, 4, 6, 9, 12, 18 and 24 in.
  • 2, 3, and 4-wire lead wire styles
  • PT100 and PT1000 RTD element
  • Stripped-end leads with other cold-end termination options
  • Dual element offered on 1/4 in. diameter probes only
RTD (PT100)-prober, -elementer og -enheder - Vis relaterede produkter

Beskrivelse

The PR-10 series has been updated with low, high, and extreme temperature ranges; all of the new models will be PR-10(L,H,E)*. The older models have been discontinued.

Omega's RTD probe with insulated lead wire has a shrink-tube strain relief support at the sheath/wire transition to provide wire flexibility and durability. This 316 stainless steel probe is offered in 2-, 3-, or 4-wire configuration. This is available in three temperature ranges covering -200°C to 600°C (-328 to 1112°F) to accommodate your specific temperature needs. Applications for this probe include liquid immersion, slurries and emulsions, granular material measurements, as well as temperature monitoring of heat bars, kilns, and pipes.
Til bestilling(Angiv modelnummer)
Vare nummer/Desc.
Antal 
Beskrivelse
PR-10L-4-100-1/8-2
57,83
Beholdning: På lager
 
4-wire RTD, -50 to 250°C, 50 mm (2 in.) length, 3.2 mm (1/8 in.) diameter
PR-10L-4-100-1/8-4
64,96
Beholdning: 5 uger 
 
4-wire RTD, -50 to 250°C, 102 mm (4 in.) length, 3.2 mm (1/8 in.) diameter
PR-10L-4-100-1/8-6
64,45
Beholdning: På lager
 
4-wire RTD, -50 to 250°C, 152 mm (6 in.) length, 3.2 mm (1/8 in.) diameter
PR-10L-4-100-1/8-12
98,73
Beholdning: 1 uge 
 
4-wire RTD, -50 to 250°C, 305 mm (12 in.) length, 3.2 mm (1/8 in.) diameter
PR-10L-4-100-1/4-2
60,06
Beholdning: På lager
 
4-wire RTD, -50 to 250°C, 50 mm (2 in.) length, 6.35 mm (1/4 in.) diameter
PR-10L-4-100-1/4-4
63,88
Beholdning: På lager
 
4-wire RTD, -50 to 250°C, 102 mm (4 in.) length, 6.35 mm (1/4 in.) diameter
PR-10L-4-100-1/4-6
76,16
Beholdning: 5 uger 
 
4-wire RTD, -50 to 250°C, 152 mm (6 in.) length, 6.35 mm (1/4 in.) diameter
PR-10L-4-100-1/4-12
93,48
Beholdning: På lager
 
4-wire RTD, -50 to 250°C, 305 mm (12 in.) length, 6.35 mm (1/4 in.) diameter
PR-10L-3-100-3/16-2-134
71,66
Beholdning: 5 uger 
 
RTD Probe with Insulated Wire and Shrink-Tube Support
Accessories
Stainless Steel Compression Fittings
SSLK-18-14T
17,20
Beholdning: 5 uger 
 
1/4 BSPT Compression Fitting for 1/8 in. Dia tube
SSLK-14-14T
16,88
Beholdning: 5 uger 
 
1/4 BSPT Compression Fitting for 1/4 in. Dia tube
SSLK-14-12T
49,61
Beholdning: 5 uger 
 
1/2 BSPT Compression Fitting for 1/4 in. Dia tube
All amounts shown in EUR

Delnummerberegner

Build Your Part Number Below
Beskrivelse af tilvalg:


(1) RANGE select from:
L for L=LOW (-50 to 250°C)
H for H=HIGH (-50 to 450°C)
E for E=EXTREME (-200 to 600°C)

(2) NUMBER OF WIRES select from:
2 for 2 WIRE
3 for 3 WIRE
4 for 4 WIRE

(3) OHMS select from:
100 for 100 OHMS
1000 for 1000 OHMS

(4) SHEATH DIAMETER select from:
1/8 for 1/8" DIAMETER
3/16 for 3/16" DIAMETER
1/4 for 1/4" DIAMETER

(5) SHEATH LENGTH select from:
2 for 2 INCHES
3 for 3 INCHES
4 for 4 INCHES
6 for 6 INCHES
9 for 9 INCHES
12 for 12 INCHES
18 for 18 INCHES
24 for 24 INCHES

(6) COLD END TERMINATION select from:
Nothing(leave field blank) for stripped leads
-RDXL6SD-CONN for connector for RDXL6SD datalogger
-TA3F for 3-pin DIN connector
-TA4F for 4-pin DIN connector
-HH804-CONNECTOR for DIN connector for use with HH-804 RTD meter
-LUG for Spade Lugs
-MTP for 3-pin mini connector
-OTP for 3-pin standard connector
Noter: Ikke alle kombinationer er nødvendigvis gyldige. Se specifikationerne for gyldige delnumre.