Cookies på Omegas websteder
Vi anvender cookies på vores websted. Disse cookies er afgørende for, at webstedet kan fungere korrekt.
Hvis du fortsætter uden at ændre dine indstillinger, antager vi, at du gerne vil modtage alle de cookies, der anvendes på dette websted. Du finder flere oplysninger om cookies ved at klikke her
Luk
Kurv  |  Kontakt  | 
GRATIS TELEFON (Kun Danmark. Alle opkald besvares på engelsk) 80 25 14 43
INTERNATIONAL(+45) 80 25 14 43

Compressed Air Dewpoint Monitor

RHB-CAC1S Series

Compressed Air Dewpoint Monitor | RHB-CAC1S Series

Compressed Air Dewpoint Monitor

Se Alt Models Below

2 year warranty CE
  • NIST Traceable
  • +/- 0.2 deg C
  • Virtually Maintenance Free
  • Easy to Install
  • Self-Monitoring
  • User-Programmable Audible and Visual Alarms and Relay Contact
  • Programmable Automatic Balance Control (ABC)
  • Widest Available Range of -60 to 50°C (-76 to 122°F)
Instrumenter til måling af relativ fugtighed - Vis relaterede produkter

Beskrivelse

These compressed air dewpoint monitors have been designed to offer the highest level of reliability and accuracy available in such systems. They are fully NIST traceable and employ a chilledmirror sensor, the most accurate dewpoint sensing scheme available, to deliver consistent drift-free measurements without regular calibrations or sensor replacement.
These compressed air monitors are complete dewpoint measuring systems. The ruggedized aluminum NEMA 12 (IP55) enclosure houses the sensor, control circuitry (including flow control) and is easily wall mounted to conserve space. Only the sample line and power connection are needed for the system to be operational.
The monitors also offer a programmable automatic balance control (ABC) cycle that corrects for the light-reducing effects of mirror contaminates and allows for continuous monitoring and virtually maintenance-free operation.

Specifications:
DEW/FROST POINT RANGE
Two-Stage (S2): -40 to 50°C (-40 to 122°F)
Three-Stage (S3): -60 to 50°C (-76 to 122°F)
Dew/Frost Point Accuracy: 0.20°C (±0.5°F)

FUNCTIONALITY
Power: 90 to 250 Vac, 50 to 400 Hz
Operating Temperature: 0 to 50°C (32 to 122°F)
Sample Connection: 1/4" compression fitting
Sample Flow Rate: 0.5 to 5 SCFH; integral flowmeter
Sample Pressure: 0 to 150 psig
(higher pressures available, consult Engineering Department)
Output: Analog: 4 to 20 mA (0 to 5 Vdc), 50 to 50°C (-58 to 122°F) or
-75 to 75°C (-103 to 167°F)
Compliance: 9.0 Vdc, 450 .
Display: Red LED, 0.5" tall; 8-digit alphanumeric

ALARM:
Audible: >98 dba @ 2'
Relay: 1 Form C, non-latching 10 A @ 240 Vac, 8 A @ 24 Vdc, 1/2 HP @ 240 Vac
Visual: Flashing “ALARM” message
Til bestilling(Angiv modelnummer)
Vare nummer/Desc.
Antal 
Beskrivelse
Quick Ship
RHB-CAC1S2C
DKK41.320,00
Beholdning: 7 uger 
 
2 Stage Dew Point Monitor
Quick Ship
RHB-CAC1S2-RHB-ATP
DKK44.265,00
Beholdning: 7 uger 
 
2 Stage Dew Point Monitor W/ATC probe
All amounts shown in DKK