Cookies på Omegas websteder
Vi anvender cookies på vores websted. Disse cookies er afgørende for, at webstedet kan fungere korrekt.
Hvis du fortsætter uden at ændre dine indstillinger, antager vi, at du gerne vil modtage alle de cookies, der anvendes på dette websted. Du finder flere oplysninger om cookies ved at klikke her
Luk
Kurv  |  Kontakt  | 
GRATIS TELEFON (Kun Danmark. Alle opkald besvares på engelsk) 80 25 14 43
INTERNATIONAL(+45) 80 25 14 43
Layer N Banner

1/2(12.7mm) Diameter Heart Cross-Section Tubular heaters

TI Series

1/2(12.7mm) Diameter Heart Cross-Section Tubular heaters | TI Series

1/2(12.7mm) Diameter Heart Cross-Section Tubular heaters

Se Alt Models Below

  • INCOLOY Sheath
  • 120, 240 and 480 Volt
  • 30 W/In2
  • 1600°F Max. Sheath Temp.
Rørformede varmeaggregater - Vis relaterede produkter

Beskrivelse

More information about how Industrial Heaters work in this link.

1/2" (12.7 mm) DIAMETER
HEART CROSS-SECTION




Watts Volts W/In2 Dimensions In. (cm) INCOLOY Sheath
Model No.
Weight
(Lb)
Sheath A Heated B
4501203016 (41)9 1/2 (24)TI-1645/120V0.5
5401203018 (46)11 1/2 (29)TI-1845/120V0.5
6351203020 (51)13 1/2 (34)TI-2045/120V0.5
7501203023 (58)16 1/2 (42)TI-2345/120V0.5
7502403023 (58)16 1/2 (42)TI-2345/240V0.5
8251203025 (64)18 1/2 (47)TI-2545/120V0.5
8252403025 (64)18 1/2 (47)TI-2545/240V0.5
9001203027 (69)20 1/2 (52)TI-2745/120V0.5
9002403027 (69)20 1/2 (52)TI-2745/240V0.5
10001203028 (71)21 1/2 (55)TI-2845/120V1
10002403028 (71)21 1/2 (55)TI-2845/240V1
11001203030 (76)23 1/2 (60)TI-3045/120V1
11002403030 (76)23 1/2 (60)TI-3045/240V1
12001203032 (81)25 1/2 (65)TI-3245/120V1
12002403032 (81)25 1/2 (65)TI-3245/240V1
12751203034 (86)27 1/2 (70)TI-3445/120V1
12752403034 (86)27 1/2 (70)TI-3445/240V1
13501203036 (91)29 1/2 (75)TI-3645/120V1
13502403036 (91)29 1/2 (75)TI-3645/240V1
14251203038 (97)31 1/2 (80)TI-3845/120V1
14252403038 (97)31 1/2 (80)TI-3845/240V1
15001203040 (102)33 1/2 (85)TI-4045/120V1.3
15002403040 (102)33 1/2 (85)TI-4045/240V1.3
16501203043 1/2 (110)37 (94)TI-4345/120V1.3
16502403043 1/2 (110)37 (94)TI-4345/240V1.3
17251203044 (112)37 1/2 (95)TI-4445/120V1.3
17252403044 (112)37 1/2 (95)TI-4445/240V1.3
18001203046 (117)39 1/2 (100)TI-4645/120V1.3
18002403046 (117)39 1/2 (100)TI-4645/240V1.3
18751203048 (122)41 1/2 (105)TI-4845/120V1.3
18752403048 (122)41 1/2 (105)TI-4845/240V1.3
19501203050 (127)43 1/2 (110)TI-5045/120V1.3
19502403050 (127)43 1/2 (110)TI-5045/240V1.3
19504803050 (127)43 1/2 (110)TI-5045/480V1.3
20001203054 1/4 (138)47 3/8 (120)TI-5445/120V1.8
20002403054 1/4 (138)47 3/8 (120)TI-5445/240V1.8
20004803054 1/4 (138)47 3/8 (120)TI-5445/480V1.8
22501203058 (147)51 1/2 (131)TI-5845/120V1.8
22502403058 (147)51 1/2 (131)TI-5845/240V1.8
22504803058 (147)51 1/2 (131)TI-5845/480V1.8
25001203060 (152)53 1/2 (136)TI-6045/120V1.8
25002403060 (152)53 1/2 (136)TI-6045/240V1.8
25004803060 (152)53 1/2 (136)TI-6045/480V1.8
27501203066 (168)59 1/2 (151)TI-6645/120V1.8
27502403066 (168)59 1/2 (151)TI-6645/240V1.8
27504803066 (168)59 1/2 (151)TI-6645/480V1.8
30001203070 (168)63 1/2 (161)TI-7045/120V1.8
30002403070 (168)63 1/2 (161)TI-7045/240V1.8
30004803070 (168)63 1/2 (161)TI-7045/480V1.8
31251203074 (188)67 1/2 (171)TI-7445/120V1.8
31252403074 (188)67 1/2 (171)TI-7445/240V1.8
31254803074 (188)67 1/2 (171)TI-7445/480V1.8
32501203078 (198)71 1/2 (182)TI-7845/120V2.3
32502403078 (198)71 1/2 (182)TI-7845/240V2.3
32504803078 (198)71 1/2 (182)TI-7845/480V2.3
33752403082 (208)75 1/2 (192)TI-8245/240V2.3
33754803082 (208)75 1/2 (192)TI-8245/480V2.3
35002403085 (216)78 1/2 (199)TI-8545/240V2.3
35004803085 (216)78 1/2 (199)TI-8545/480V2.3
36252403090 (229)83 1/2 (212)TI-9045/240V2.3
36254803090 (229)83 1/2 (212)TI-9045/480V2.3
37502403094 (239)87 1/2 (222)TI-9445/240V2.3
37504803094 (239)87 1/2 (222)TI-9445/480V2.3
38752403098 (248)91 1/2 (232)TI-9845/240V2.3
38754803098 (248)91 1/2 (232)TI-9845/480V2.3
400024030100 (254)93 1/2 (237)TI-10045/240V3.3
400048030100 (254)93 1/2 (237)TI-10045/480V3.3
450024030108 (274)101 1/2 (258)TI-10845/240V3.3
450048030108 (274)101 1/2 (258)TI-10845/480V3.3
475024030112 (284)105 1/2 (268)TI-11245/240V3.3
475048030112 (284)105 1/2 (268)TI-11245/480V3.3
500024030118 (300)111 1/2 (283)TI-11845/240V3.3
500048030118 (300)111 1/2 (283)TI-11845/480V3.3
525024030130 (330)123 1/2 (314)TI-13045/240V3.3
525048030130 (330)123 1/2 (314)TI-13045/480V3.3
550024030136 (345)129 1/2 (329)TI-13645/240V3.3
550048030136 (345)129 1/2 (329)TI-13645/480V3.3
575024030142 (361)135 1/2 (344)TI-14245/240V4.3
575048030142 (361)135 1/2 (344)TI-14245/480V4.3
600048030148 (376)141 1/2 (359)TI-14845/480V4.3
625048030156 (396)149 1/2 (380)TI-15645/480V4.3
650048030164 (417)157 1/2 (400)TI-16445/480V4.3
675048030172 (437)165 1/2 (420)TI-17245/480V4.3



3/8" (9.5 mm) DIAMETER
HEART CROSS-SECTION




Watts Volts W/In2 Dimensions In. (cm) INCOLOY Sheath
Model No.
Weight
(Lb)
Sheath A Heated B
3001203016 (41)9 1/2 (24)TI-1648/120V0.4
3501203018 (46)11 1/2 (29)TI-1848/120V0.4
4501203020 (51)13 1/2 (34)TI-2048/120V0.4
5001203022 (56)15 1/2 (39)TI-2248/120V0.4
6501203025 (64)18 1/2 (47)TI-2548/120V0.4
6502403025 (64)18 1/2 (47)TI-2548/240V0.4
7001203027 (69)20 1/2 (52)TI-2748/120V0.4
7002403027 (69)20 1/2 (52)TI-2748/240V0.4
7501203028 (71)21 1/2 (55)TI-2848/120V0.8
7502403028 (71)21 1/2 (55)TI-2848/240V0.8
8001203030 (76)23 1/2 (60)TI-3048/120V0.8
8002403030 (76)23 1/2 (60)TI-3048/240V0.8
8501203032 (81)25 1/2 (65)TI-3248/120V0.8
8502403032 (81)25 1/2 (65)TI-3248/240V0.8
9001203034 (86)27 1/2 (70)TI-3448/120V0.8
9002403034 (86)27 1/2 (70)TI-3448/240V0.8
10001203036 (91)29 1/2 (75)TI-3648/120V0.8
10002403036 (91)29 1/2 (75)TI-3648/240V0.8
10501203038 (97)31 1/2 (80)TI-3848/120V0.8
10502403038 (97)31 1/2 (80)TI-3848/240V0.8
11001203040 (102)33 1/2 (85)TI-4048/120V1
11002403040 (102)33 1/2 (85)TI-4048/240V1
12001203042 (107)35 1/2 (90)TI-4248/120V1
12002403042 (107)35 1/2 (90)TI-4248/240V1
12501203044 (112)37 1/2 (95)TI-4448/120V1
12502403044 (112)37 1/2 (95)TI-4448/240V1
13001203046 (117)39 1/2 (100)TI-4648/120V1
13002403046 (117)39 1/2 (100)TI-4648/240V1
13501203048 (122)41 1/2 (105)TI-4848/120V1
13502403048 (122)41 1/2 (105)TI-4848/240V1
14501203050 (127)43 1/2 (110)TI-5048/120V1
14502403050 (127)43 1/2 (110)TI-5048/240V1
14504803050 (127)43 1/2 (110)TI-5048/480V1
15501203054 (137)47 1/2 (121)TI-5448/120V1.3
15502403054 (137)47 1/2 (121)TI-5448/240V1.3
15504803054 (137)47 1/2 (121)TI-5448/480V1.3
17001203058 (147)51 1/2 (131)TI-5848/120V1.3
17002403058 (147)51 1/2 (131)TI-5848/240V1.3
17004803058 (147)51 1/2 (131)TI-5848/480V1.3
18501203062 (157)55 1/2 (141)TI-6248/120V1.3
18502403062 (157)55 1/2 (141)TI-6248/240V1.3
18504803062 (157)55 1/ (141)TI-6248/480V1.3
19501203066 (168)59 1/2 (151)TI-6648/120V1.3
19502403066 (168)59 1/2 (151)TI-6648/240V1.3
19504803066 (168)59 1/2 (151)TI-6648/480V1.3
21001203070 (178)63 1/2 (161)TI-7048/120V1.3
21002403070 (178)63 1/2 (161)TI-7048/240V1.3
21004803070 (178)63 1/2 (161)TI-7048/480V1.3
22501203074 (188)67 1/2 (171)TI-7448/120V1.3
22502403074 (188)67 1/2 (171)TI-7448/240V1.3
22504803074 (188)67 1/2 (171)TI-7448/480V1.3
23501203078 (198)71 1/2 (182)TI-7848/120V1.8
23502403078 (198)71 1/2 (182)TI-7848/240V1.8
23504803078 (198)71 1/2 (182)TI-7848/480V1.8
25002403082 (208)75 1/2 (192)TI-8248/240V1.8
25004803082 (208)75 1/2 (192)TI-8248/480V1.8
26002403086 (218)79 1/2 (202)TI-8648/240V1.8
26004803086 (218)79 1/2 (202)TI-8648/480V1.8
27502403090 (229)83 1/2 (212)TI-9048/240V1.8
27504803090 (229)83 1/2 (212)TI-9048/480V1.8
29002403094 (239)87 1/2 (222)TI-9448/240V1.8
29004803094 (239)87 1/2 (222)TI-9448/480V1.8
30002403098 (249)91 1/2 (232)TI-9848/240V1.8
30004803098 (249)91 1/2 (232)TI-9848/480V1.8
315024030102 (259)95 1/2 (243)TI-10248/240V2.5
315048030102 (259)95 1/2 (243)TI-10248/480V2.5
330024030106 (269)99 1/2 (253)TI-10648/240V2.5
330048030106 (269)99 1/2 (253)TI-10648/480V2.5
350024030112 (284)105 1/2 (268)TI-11248/240V2.5
350048030112 (284)105 1/2 (268)TI-11248/480V2.5
365024030118 (300)111 1/2 (283)TI-11848/240V2.5
365048030118 (300)111 1/2 (283)TI-11848/480V2.5
390024030124 (315)117 1/2 (298)TI-12448/240V2.5
390048030124 (315)117 1/2 (298)TI-12448/480V2.5
410024030130 (330)123 1/2 (314)TI-13048/240V2.5
410048030130 (330)123 1/2 (314)TI-13048/480V2.5
430024030136 (345)129 1/2 (329)TI-13648/240V3.8
430048030136 (345)129 1/2 (329)TI-13648/480V3.8
450024030142 (361)135 1/2 (344)TI-14248/240V3.8
450048030142 (361)135 1/2 (344)TI-14248/480V3.8
470048030148 (376)141 1/2 (359)TI-14848/480V3.8
495048030156 (396)149 1/2 (380)TI-15648/480V3.8
520048030164 (417)157 1/2 (400)TI-16448/480V3.8
535048030172 (437)165 1/ 2(420)TI-17248/480V3.8
Til bestilling(Angiv modelnummer)
Vare nummer/Desc.
Antal 
Beskrivelse
Example part numbers are shown below. For additional configurations see the Part Number Builder below this table.
TI-1645/120V
Kontakt salgsafdelingen    
Beholdning: 
 
 
Heater, 450 W, 120 V
TI-2545/240V
Kontakt salgsafdelingen    
Beholdning: 
 
 
Heater, 825 W, 240 V
TI-7045/480V
Kontakt salgsafdelingen    
Beholdning: 
 
 
Heater, 3000 W, 480 V
TI-11245/480V
Kontakt salgsafdelingen    
Beholdning: 
 
 
Heater, 4750 W, 480 V
TI-3248/120V
Kontakt salgsafdelingen    
Beholdning: 
 
 
Heater, 850 W, 120 V
TI-9048/240V
Kontakt salgsafdelingen    
Beholdning: 
 
 
Heater, 2750 W, 240 V
All amounts shown in EUR

Delnummerberegner

Build Your Part Number Below
Beskrivelse af tilvalg:


(1) Sheath A select from:
16 for 16 in.
18 for 18 in.
20 for 20 in.
22 for 22 in.
23 for 23 in.
25 for 25 in.
27 for 27 in.
28 for 28 in.
30 for 30 in.
32 for 32 in.
34 for 34 in.
36 for 36 in.
38 for 38 in.
40 for 40 in.
42 for 42 in.
43 for 43 in.
44 for 44 in.
46 for 46 in.
48 for 48 in.
50 for 50 in.
54 for 54 in.
58 for 58 in.
60 for 60 in.
62 for 62 in.
66 for 66 in.
70 for 70 in.
74 for 74 in.
78 for 78 in.
82 for 82 in.
85 for 85 in.
86 for 86 in.
90 for 90 in.
94 for 94 in.
98 for 98 in.
100 for 100 in.
102 for 102 in.
106 for 106 in.
108 for 108 in.
112 for 112 in.
118 for 118 in.
124 for 124 in.
130 for 130 in.
136 for 136 in.
142 for 142 in.
148 for 148 in.
156 for 156 in.
164 for 164 in.
172 for 172 in.

(2) Code in Part Number select from:
45 for code 45
48 for code 48

(3) Voltage select from:
120V for 120 V
240V for 240 V
480V for 480 V
Noter: Ikke alle kombinationer er nødvendigvis gyldige. Se specifikationerne for gyldige delnumre.