Rugged Thermocouple Transition Joint Probe with Inconel® 600 Braid over Silica Ceramic-Insulated Lead Wire

TJ36-XSiB Series

Rugged Thermocouple Transition Joint Probe with Inconel® 600 Braid over Silica Ceramic-Insulated Lead Wire | TJ36-XSiB Series

106,83 TJ36-CASS-14U-12-CC-XSIB

  • 304 SS and Inconel® 600 in Stock
  • 1 m (40 in.) Lead Length
  • Manufactured with Super OMEGACLAD™ XL Compacted Mineral Insulation Cable for Long-Lasting Performance in Harsh Conditions
  • Inconel® Overbraided Silica Ceramic and Ceramic Insulated Lead Wire
  • Lead Wire Rated to 815°C (1500°)
  • Spring Strain Relief Prevents "Pinching" of the Wire

Beskrivelse

Click here if you want to know more about thermocouples.


For long life, drift-free operation, choose Super OMEGACLAD™ XL mineral insulated thermocouple cable and our rugged transition joint probes, which are available in Type K and N calibrations. Inconel® overbraided silica ceramic and ceramic insulation provides cost-effective operation of the transition joint at temperatures up to 815°C (1500°F). See the highlighted section in the table.

Calibration
ANSI Code
Sheath
Materials
Sheath Dia.
mm (in.)
T/C Junction
Upper Temp.
°C (°F)
Model Number
(See notes, below)
K
CHROMEGA™-
ALOMEGA™
304SS 1.59 (1/16)
3.18 (1/8)
4.78 (3/16)
6.35 (1/4)
899 (1650)
899 (1650)
899 (1650)
899 (1650)
TJ36-CASS-116(*)-(**)-CC-XSIB
TJ36-CASS-18(*)-(**)-CC-XSIB
TJ36-CASS-316(*)-(**)-CC-XSIB
TJ36-CASS-14(*)-(**)-CC-XSIB
INC600 1.59 (1/16)
3.18 (1/8)
4.78 (3/16)
6.35 (1/4)
921 (1690)
1071 (1960)
1149 (2100)
1149 (2100)
TJ36-CAIN-116(*)-(**)-CC-XSIB
TJ36-CAIN-18(*)-(**)-CC-XSIB
TJ36-CAIN-316(*)-(**)-CC-XSIB
TJ36-CAIN-14(*)-(**)-CC-XSIB
Super
OMEGACLAD™
XL
1.59 (1/16)
3.18 (1/8)
4.78 (3/16)
6.35 (1/4)
1038 (1900)
1149 (2100)
1204 (2200)
1204 (2200)
TJ36-CAXL-116(*)-(**)-CC-XSIB
TJ36-CAXL-18(*)-(**)-CC-XSIB
TJ36-CAXL-316(*)-(**)-CC-XSIB
TJ36-CAXL-14(*)-(**)-CC-XSIB
J
Iron-
Constantan
304SS 1.59 (1/16)
3.18 (1/8)
4.78 (3/16)
6.35 (1/4)
441 (825)
521 (970)
621 (1150)
721 (1330)
TJ36-ICSS-116(*)-(**)-CC-XSIB
TJ36-ICSS-18(*)-(**)-CC-XSIB
TJ36-ICSS-316(*)-(**)-CC-XSIB
TJ36-ICSS-14(*)-(**)-CC-XSIB
T
Copper-
Constantan
304SS 1.59 (1/16)
3.18 (1/8)
4.78 (3/16)
6.35 (1/4)
260 (500)
316 (600)
371 (700)
371 (700)
TJ36-CPSS-116(*)-(**)-CC-XSIB
TJ36-CPSS-18(*)-(**)-CC-XSIB
TJ36-CPSS-316(*)-(**)-CC-XSIB
TJ36-CPSS-14(*)-(**)-CC-XSIB
Notes: *Specify Junction: (G)rounded, (E)xposed or or (U)ngrounded.
**Specify length in inches: 6 for 150 mm (6 in.), 12 for 300 mm (12 in.), or 18 for 450 mm (18 in.).
Super OMEGACLAD™ XL probes (highlighted in yellow) are also available in N calibration; substitute NN for CA in Model Number. See ordering examples below.
Til bestilling(Angiv modelnummer)

Andre har købt: Du kan klikke på dette ikon og få vist en liste over produkter, som andre har købt sammen med denne model.

Vare nummer/Desc.
Antal 
Beskrivelse
  
TJ36-CASS-116G-12-CC-XSIB
88,25
Beholdning: 4 uger 
 
TJ36 Joint Probe with Inconel® 600 braid over ceramic-insulated lead wire, stripped-lead termination; 304 SS probe; Type K, grounded junction; 1.5 mm (1/16 in.) probe dia., 300 mm (12 in.) length
  
TJ36-CAIN-14U-12-CC-XSIB
104,76
Beholdning: 4 uger 
 
TJ36 Joint Probe with Inconel® 600 braid over ceramic-insulated lead wire, stripped-lead termination; Inconel® probe; Type K, ungrounded junction; 6 mm (1/4 in.) probe dia., 300 mm (12 in.) length
Click to expand/minimize a list of what others bought with theTJ36-CAXL-316U-6-CC-XSIB
TJ36-CAXL-316U-6-CC-XSIB
98,14
Beholdning: 4 uger 
 
TJ36 Joint Probe with Inconel® 600 braid over ceramic-insulated lead wire, stripped-lead termination; Super OMEGACLAD™ XL probe; Type K, ungrounded junction; 4.5 mm (3/16 in.) probe dia., 150 mm (6 in.) length
  
TJ36-ICSS-18E-12-CC-XSIB
88,25
Beholdning: 4 uger 
 
TJ36 Joint Probe with Inconel® 600 braid over ceramic-insulated lead wire, stripped-lead termination; 304 SS probe; Type J, exposed junction; 3 mm (1/8 in.) probe dia., 300 mm (12 in.) length
  
TJ36-CPSS-14G-12-CC-XSIB
87,95
Beholdning: 5 uger 
 
TJ36 Joint Probe with Inconel® 600 braid over ceramic-insulated lead wire, stripped-lead termination; 304 SS probe; Type T, grounded junction; 6 mm (1/4 in.) probe dia., 300 mm (12 in.) length
  
TJ36-NNXL-14U-12-CC-XSIB.
Kontakt salgsafdelingen    
Beholdning: 
 
 
TJ36 Joint Probe with Inconel® 600 braid over ceramic-insulated lead wire, stripped-lead termination; 304 SS probe; Type N, ungrounded junction; 6 mm (1/4 in.) probe dia., 300 mm (12 in.) length
All amounts shown in EUR
We noticed you are from the US. Visit your local site for regional offers and live support.