Handheld Volatile Organic Compound (VOC) Meter

HHAQ-107

HHAQ-107 VOC monitor | HHAQ-107

HHAQ-107 VOC monitor

DKK3.530,00 HHAQ-107

1 year warranty CE
  • Metal-Oxide Semi-Conductor Sensor within Vented Ball Housing Detects Ammonia, Toluene, Ethanol, Hydrogen Sulfide (H2S) and Cigarette Smoke
  • Make Total VOC Concentration Measurements, Ambient Temperature, Relative Humidity (RH), Dew Point and Wet Bulb Temperatures
  • Logs Up to 32,000 Data Points
  • Powerful Data Logging Software
  • Adjustable High VOC Concentration Audible Alarm
  • Min/Max Memory (for All Measured Parameters) and Data Hold
  • Separate Automated Procedures for VOC Zero Adjustment and Background Calibration
  • Manually Off-Settable Temperature and RH Sensor Drift
  • Large Backlit Dual-Readout LCD
  • Tripod Mountable
nye pH-, flow- og miljøprodukter - Vis relaterede produkter

Beskrivelse

The HHAQ-107 is ideal for making general measurements of mixed gas volatile organic compound (VOC) levels as part of an indoor air quality (IAQ) maintenance program. Much less expensive than photo-ionization meters designed to make precise measurements of VOC levels from a single gas. Small and light weight with a tripod mount fitting, the HHAQ-107 is a versatile tool for HVAC and IAQ technicians. The meters storage capacity can be entirely devoted to VOC readings or split 3 ways for VOC, ambient temperature and relative humidity. The HHAQ-107 incudes powerful data logging software for downloading readings to a PC and printing in table or graph form.

SPECIFICATIONS
VOC Measurement Range/Resolution: 0 to 50/0.01 ppm
VOC Warmup Time: 10 minutes first use, 2 minutes thereafter
VOC Sensor Type/Longevity: Metal-oxide semiconductor/5 years (typical)
Temperature Measurement Range: -10 to 50°C (14 to 122°F)
Temperature Measurement Accuracy/Resolution: ±0.6°C (1.2°F)/0.1°
RH Measurement Range: 10 to 90% RH
RH Measurement Accuracy/Resolution: ±5% of reading at 25°C; ±7% of reading elsewhere in range/0.1% RH
Dew Point Measurement Range: -73 to 47°C (-99.2 to 118°F)
Wet Bulb Measurement Range: -11 to 48.2°C (12.2 to 118.8°F)
Data Logging Capacity: 32,004 points
Display Type/Size: Dual readout LCD/51 mm diagonal
Auto Power-Off Trigger: 15 minutes of front-panel inactivity (can be disabled)
Operating Temperature: 0 to 50°C at 0 to 95% RH, non-condensing
Dimensions: 210 L x 60 W x 25 mm D
Weight: 204 g, including batteries
Power Source: (6) “AAA” batteries (included) or optional ac adaptor
Til bestilling(Angiv modelnummer)
Vare nummer/Desc.
Antal 
Beskrivelse
Quick Ship
HHAQ-107
DKK3.530,00
Beholdning: På lager
 
Handheld volatile organic compound (VOC) meter
Quick Ship
MN2400
DKK45,00
Beholdning: 1 uge 
 
Replacement “AAA” batteries 2 per pack, 3 packs needed
All amounts shown in DKK
Noter: Comes complete with meter, PC-compatible data logging program on mini-disc, USB cable, soft pouch, (6) “AAA” batteries and operator’s manual.