Beskrivelse af tilvalg:
(1)
Input and Output Type select from:DT for DC Displacement Transducer Input
LTC for Linearized Thermocouple Input
ITC for Non-Linearized Thermocouple Input
IP for RTD Input (Pt100 Ohm 2 or 3 Wire)
IC for RTD Input (Copper 2 or 3 Wire)
IN for RTD Input (Nickel 2 or 3 Wire)
IP4 for RTD Input (Pt100 Ohm 4 Wire)
IV for Voltage Input
IFI for Frequency Input
IMV for Millivolt Input
TC for 2-Wire Transmitter
PT for Potentiometer Input
WMV for Wideband Millivolt Input
WBS for Strain Gage Input
II for Current Input
WV for Wideband Voltage Input
IVI for Current Output
(2)
Input and Output Range select from:1 for Input ±1 Vdc (DT Only)
2 for Input ±2 Vdc (DT Only)
3 for Input ±3 Vdc (DT Only)
4 for Input ±4 Vdc (DT Only)
5 for Input ±5 Vdc (DT Only)
6 for Input ±6 Vdc (DT Only)
7 for Input ±7 Vdc (DT Only)
8 for Input ±8 Vdc (DT Only)
9 for Input ±9 Vdc (DT Only)
10 for Input ±10 Vdc (DT Only)
J1 for Thermocouple Type J 0 to 760°C (LTC Only)
J2 for Thermocouple Type J 100 to 300°C (LTC Only)
J3 for Thermocouple Type J 0 to 500°C (LTC Only)
K1 for Thermocouple Type K 0 to 1000°C (LTC Only)
K2 for Thermocouple Type K 0 to 500°C (LTC Only)
T1 for Thermocouple Type T -100 to 400°C (LTC Only)
T2 for Thermocouple Type T 0 to 200°C (LTC Only)
E for Thermocouple Type E 0 to 1000°C (LTC Only)
R for Thermocouple Type R 500 to 1750°C (LTC Only)
S for Thermocouple Type S 500 to 1750°C (LTC Only)
B for Thermocouple Type B 500 to 1800°C (LTC Only)
J for Thermocouple Type J -100 to 760°C (ITC Only)
K for Thermocouple Type K -100 to 1350°C (ITC Only)
T for Thermocouple Type T -100 to 400°C (ITC Only)
E for Thermocouple Type E 0 to 900°C (ITC Only)
R for Thermocouple Type R 0 to 1750°C (ITC Only)
S for Thermocouple Type S 0 to 1750°C (ITC Only)
B for Thermocouple Type B 0 to 1800°C (ITC Only)
C1 for Thermocouple Type C 350 to 1300°C (ITC Only)
N1 for Thermocouple Type N -100 to 1300°C (ITC Only)
N100 for Input -100 to 100°C (IP and IP4 Only)
100 for Input 0 to 100°C (IP and IP4 Only)
200 for Input 0 to 200°C (IP and IP4 Only)
600 for Input 0 to 600°C (IP and IP4 Only)
120 for Input 0 to 120°C (IC Only)
300 for Input 0 to 300°C (IN Only)
1A for Input ±1 V (IV and WV Only)
5A for Input ±5 V (IV and WV Only)
10A for Input ±10 V (IV and WV Only)
1B for Input ±1 V (IV and WV Only)
5B for Input ±5 V (IV and WV Only)
10B for Input ±10 V (IV and WV Only)
20A for Input ±20 Vdc (IV and WV Only)
40A for Input ±40 Vdc (IV and WV Only)
20B for Input ±20 Vdc (IV and WV Only)
40B for Input ±40 Vdc (IV and WV Only)
500 for Input 0 to 500 Hz (IFI Only)
1K for Input 0 to 1 KHz (IFI Only)
3K for Input 0 to 3 KHz (IFI Only)
5K for Input 0 to 5 KHz (IFI Only)
10K for Input 0 to 10 KHz (IFI Only)
25K for Input 0 to 25 KHz (IFI Only)
50K for Input 0 to 50 KHz (IFI Only)
100K for Input 0 to 100 KHz (IFI Only)
10A for Input ±10 mV Output ±5 Vdc (IMV and WMV Only)
50A for Input ±50 mV Output ±5 Vdc (IMV and WMV Only)
100A for Input ±100 mV Output ±5 Vdc (IMV and WMV Only)
10B for Input ±10 mV Output ±0-5 Vdc (IMV and WMV Only)
50B for Input ±50 mV Output ±0-5 Vdc (IMV and WMV Only)
100B for Input ±100 mV Output ±0-5 Vdc (IMV and WMV Only)
100 for Input 100 Ohm (PT Only)
1000 for Input 500 Ohm (PT Only)
1K for Input 1K Ohm (PT Only)
10K for Input 10K Ohm (PT Only)
1 for Input 4 to 20 mA Output 1 to 5 Vdc (TC Only)
2 for Input 4 to 20 mA Output 2 to 10 Vdc (TC Only)
1 for Full Bridge Input ±30 mV @ 10 V Exc (WBS Only)
2 for Full Bridge Input ±20 mV @ 10V Exc (WBS Only)
3 for Half Bridge Input ±20 mV @ 10V Exc (WBS Only)
4/20 for Input 4 to 20 mA (II Only)
0/20 for Input 0 to 20 mA (II Only)
B0 for Input 0 to 5 Vdc Output 0-20 mA (IVI Only)
A0 for Input ±5 Vdc (IVI Only)
B4 for Input 0 to 5 Vdc Ouput 4-20 mA (IVI Only)
A4 for Input ±5 Vdc Ouput 4-20 mA (IVI Only)
(3)
Additional Option (IC Only) select from:Nothing(leave field blank) for None
-01 for 10 Ohm @ 0°C
-02 for 10 Ohm @ 25°C
Noter: Ikke alle kombinationer er nødvendigvis gyldige. Se specifikationerne for gyldige delnumre.