Cookies på Omegas websteder
Vi anvender cookies på vores websted. Disse cookies er afgørende for, at webstedet kan fungere korrekt.
Hvis du fortsætter uden at ændre dine indstillinger, antager vi, at du gerne vil modtage alle de cookies, der anvendes på dette websted. Du finder flere oplysninger om cookies ved at klikke her
Luk
Kurv  |  Kontakt  | 
GRATIS TELEFON (Kun Danmark. Alle opkald besvares på engelsk) 80 25 14 43
INTERNATIONAL(+45) 80 25 14 43
Layer N Banner

PX2670I - Discontinued

PX2670I

 | PX2670I

Se Alt Models Below

1 year warranty CE
  • 0.4% Accuracy Improves Energy Management Systems
  • 4-20 mA Output Is Compatible with Most 2-Wire Control Systems
  • Optional 3 1 /2 -Digit LCD Dispplay
  • IP65/NEMA-4 Enclosure
  • 11-Point Calibration Certificate Standard

Beskrivelse

OMEGAfs PX2670 Series pressure transducers sense either differential or gage pressure and convert this pressure to a highly accurate electrical signal. Used in building energy management systems, these transducers are capable of measuring pressures and flows with a high degree of accuracy to improve overall system efficiency. The units are temperature compensated to better than 0.33% FS/‹F over the range of 40 to 150‹F and have an IP65/NEMA-4 rated package to withstand environmental effects. A 31.2-digit LCD display is optional.

SPECIFICATIONS
Excitation: 24 Vdc nominal
Max: 30.0 + (0.004 x Loop Resistance .) Vdc
Min: 14.0 + (0.02 x Loop Resistance .) Vdc
Loop Resistance: 0 to 800 .
Output: 4-20 mA (2-wire) with internal zero and span adjustments
Accuracy: }0.4% FS at constant temperature (includes linearity, repeatability, and hysteresis)
Linearity: }0.33% FS
Hysteresis: 0.020% FS
Repeatability: 0.10% FS
Output Impedance: <100 .
Operable Temperature Range: 0 to 150‹F (-18 to 65‹C) Compensated Temperature Range: 40 to 150‹F (5 to 65‹C)
Thermal Span Effect: }0.033%FS/‹F
Sensor: Capacitance
Position Effects: Range Zero Offset (%FS/G) 0-10 inH2O .03 0-1 inH2O 1 0-0.1 inH2O 4
Maximum Line Pressure: 10 psi
Overpressure:
Negative Direction: 10 psi
Positive Direction: 10 psi
Wetted Parts: Air and non-conductive gas
Pressure Port: 3.16" OD tube fitting for 1.4" push-on tube
Electrical Connection: Internal Terminal Strip with Strain Relief
Weight: 11 oz (310 g)
Til bestilling(Angiv modelnummer)
Vare nummer/Desc.
Antal 
Beskrivelse
PX2670-0.1DI
Kontakt salgsafdelingen    
Beholdning: 
 
 
very low differential transducer with a range from 0 to 0.1 in-H2O and a 4-20 mA output
PX2670-0.25DI
Kontakt salgsafdelingen    
Beholdning: 
 
 
very low differential transducer with a range from 0 to 0.25 in-H2O and a 4-20 mA output
PX2670-0.5DI-M
Kontakt salgsafdelingen    
Beholdning: 
 
 
very low differential transducer with a range from 0 to 0.5 in-H2O and a 4-20 mA output with an LCD Display
PX2670-0.5BDI
Kontakt salgsafdelingen    
Beholdning: 
 
 
very low differential transducer with a bidirectional range of ±0.5 in-H2O and a 4-20 mA output
PX2670-0.5BDI-M
Kontakt salgsafdelingen    
Beholdning: 
 
 
very low differential transducer with a bidirectional range of ±0.5 in-H2O and a 4-20 mA output with an LCD Display
All amounts shown in EUR
Noter: All models come with complete operator’s manual.

Delnummerberegner

Build Your Part Number Below
Beskrivelse af tilvalg:


(1) Range (inH2O) select from:
0.1 for 0-0.1
0.25 for 0-0.25
0.5 for 0-0.5
1 for 0-1
2.5 for 0-2.5
5 for 0-5
10 for 0-10
25 for 0-25
0.1B for ±0.1
0.25B for ±0.25
0.5B for ±0.5
1B for ±1
2.5B for ±2.5
5B for ±5

(2) Display select from:
for Leave Blank For No Display
-M for LCD Display
Noter: Ikke alle kombinationer er nødvendigvis gyldige. Se specifikationerne for gyldige delnumre.
We noticed you are from the US. Visit your local site for regional offers and live support.