Bærbare Doppler-ultralydsflowmålere

FD613 and FD614

Bærbare Doppler-ultralydsflowmålere | FD613 and FD614

Bærbare Doppler-ultralydsflowmålere

Se Alt Models Below

1 year warranty CE
  • 100 PPM MED 100 mikron til partikler eller bobler kræves (ikke til rene væsker)
  • Batteridrevet
  • Ikke-invasiv transducer til påspænding
  • Mikroprocessorbaseret signalbetingningselektronik
  • Display med store tegn
  • Hastighedsenheder kan vælges af brugeren (fod/sek.eller m/sek.)
  • Måler væskehastigheder fra 0,3 til 30,0 fod/sek. (0,10 til 9,.00 m/sek.)
  • 100:1 turndown-forhold
  • Rørstørrelser fra 6,3 mm (0,25")
  • CE-godkendelse basismodel som ekstraudstyr
  • NIST-standard
Håndholdte målere - Vis relaterede produkter

Beskrivelse

The FD610 Series ultrasonic flow meter features advanced Trans-Phase measuring technology, providing accurate and reliable flow velocity assessments in closed piping systems. The FD610 Series utilizes a non-invasive clamp-on transducer which is placed on the outside of a pipe. Within seconds, the large 18 mm (0.7") LCD provides stable flowrate readings in feet per second or meters per second. This product operates on metal or plastic pipes containing liquids with more than 100 ppm of 100 micron or larger suspended solids or entrained gases.
PRINCIPLE OF OPERATION
The FD610 Series flowmeter utilizes an advanced Trans-Phase measuring technique, providing accurate, non-invasive fluid velocity assessment without opening the pipe. The FD610 Series utilizes two piezoelectric crystals contained within one transducer to transmit ultrasonic energy into the fluid stream and receive back energy reflected off discontinuities (suspended particles or entrained gases) within the moving liquid. Transformations that result from the energy reflections are processed and converted to a measurement of fluid velocity by the sophisticated software algorithm. The processor also controls all operations of the instrument from its ultra-efficient battery management circuitry to a proprietary FIR (Finite Impulse Response) filtration program.

SPECIFICATIONS
Supply Voltage: Battery powered, non-rechargeable alkaline, four AA cells, providing over 30 hours of continuous operation
Flow Range: 0.30 to 30.00 FPS (0.10 to 9.00 MPS)
Display: Single line – four-digit LCD readout of velocity (18 mm (0.7") digits), signal strength, measuring units, and low battery indication
Temperature: -20 to 60°C (-28 to 140°F)
Enclosure Rating/Dimensions: NEMA-12X ABS plastic; 200 H x 100 W x 38 mm H (7.76 x 4 x 1.5")
Weight: 0.7 kg (1.5 lb)
Accuracy: ±2% full scale
Transducer
Transducer Material: Plated body; ULTEM 1000 sensor material
Cable: 2 m (6.6 ft) cable and connector
Temperature: -40 to 82°C (-40 to 180°F)
Humidity: 0 to 95% non-condensing
Mounting Method: Clamp-on style with DOW 111 coupling compound


Please download PDF file full product specifications